OBJECTIVES

This study sought to determine if combining the Seattle Heart Failure Model (SHFM-D) and cardiac magnetic resonance (CMR) provides complementary prognostic data for patients with cardiac resynchronization therapy (CRT) defibrillators.

BACKGROUND

The SHFM-D is among the most widely used risk stratification models for overall survival in patients with heart failure and implantable cardioverter-defibrillators (ICDs), and CMR provides highly detailed information regarding cardiac structure and function.

METHODS

CMR Displacement Encoding with Stimulated Echoes (DENSE) strain imaging was used to generate the circumferential uniformity ratio estimate with singular value decomposition (CURE-SVD) circumferential strain dyssynchrony parameter, and the SHFM-D was determined from clinical parameters. Multivariable Cox proportional hazards regression was used to determine adjusted hazard ratios and time-dependent areas under the curve for the primary endpoint of death, heart transplantation, left ventricular assist device, or appropriate ICD therapies.

RESULTS

The cohort consisted of 100 patients (65.5 [interquartile range 57.7 to 72.7] years; 29% female), of whom 47% had the primary clinical endpoint and 18% had appropriate ICD therapies during a median follow-up of 5.3 years. CURE-SVD and the SHFM-D were independently associated with the primary endpoint (SHFM-D: hazard ratio: 1.47/SD; 95% confidence interval: 1.06 to 2.03; p = 0.02) (CURE-SVD: hazard ratio: 1.54/SD; 95% confidence interval: 1.12 to 2.11; p = 0.009). Furthermore, a favorable prognostic group (Group A, with CURE-SVD <0.60 and SHFM-D <0.70) comprising approximately one-third of the patients had a very low rate of appropriate ICD therapies (1.5% per year) and a greater (90%) 4-year survival compared with Group B (CURE-SVD ≥0.60 or SHFM-D ≥0.70) patients (p = 0.02). CURE-SVD with DENSE had a stronger correlation with CRT response (r = -0.57; p < 0.0001) than CURE-SVD with feature tracking (r = -0.28; p = 0.004).

CONCLUSIONS

A combined approach to risk stratification using CMR DENSE strain imaging and a widely used clinical risk model, the SHFM-D, proved to be effective in this cohort of patients referred for CRT defibrillators. The combined use of CMR and clinical risk models represents a promising and novel paradigm to inform prognosis and device selection in the future.

Для цитирования: Bilchick Kenneth C, Auger Daniel A, Abdishektaei Mohammad, Mathew Roshin, Sohn Min-Woong, Cai Xiaoying, Sun Changyu, Narayan Aditya, Malhotra Rohit, Darby Andrew, Mangrum J Michael, Mehta Nishaki, Ferguson John, Mazimba Sula, Mason Pamela K, Kramer Christopher M, Levy Wayne C, Epstein Frederick H. CMR DENSE and the Seattle Heart Failure Model Inform Survival and Arrhythmia Risk After CRT.. JACC. Cardiovascular imaging. 2019. DOI: 10.1016/j.jcmg.2019.10.017.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.