DOI 10.1016/j.jcin.2019.05.055
Transcatheter Valve SELECTion in Patients With Right Bundle Branch Block and Impact on Pacemaker Implantations.
Аннотация
OBJECTIVES
This study sought to evaluate the impact of the ACURATE neo (NEO) (Boston Scientific, Marlborough, Massachusetts) versus SAPIEN 3 (S3) (Edwards Lifesciences, Irvine, California) on permanent pacemaker implantation (PPI) in patients with pre-existing right bundle branch block (RBBB) after transcatheter aortic valve replacement.
BACKGROUND
Pre-existing RBBB is the strongest patient-related predictor for PPI after transcatheter aortic valve replacement. No comparison of newer-generation transcatheter heart valves with regard to PPI in these patients exists.
METHODS
This multicenter registry includes 4,305 patients; 296 (6.9%) had pre-existent RBBB and no pacemaker at baseline and formed the study population. The primary endpoint was new PPI at 30 days. The association of NEO versus S3 with PPI was assessed using binary logistic regression analyses and inverse probability treatment weighting in a propensity-matched population.
RESULTS
The 30-day PPI rate was 39.2%. The S3 and NEO were used in 66.9% and 33.1%, respectively. The NEO was associated with lower rates of PPI compared with the S3 (29.6% vs. 43.9%; p = 0.025; odds ratio [OR]: 0.54; 95% confidence interval [CI]: 0.32 to 0.89; p = 0.018), after multivariable adjustment (OR: 0.48; 95% CI: 0.26 to 0.86; p = 0.014), and in the inverse probability treatment weighting analysis (OR: 0.37; 95% CI: 0.25 to 0.55; p < 0.001). There was no difference in device failure (8.2% vs. 6.6%; p = 0.792) or in-hospital course. In the propensity-matched population, PPI rate was also lower in the NEO versus S3 (23.1% vs. 44.6%; p = 0.016; OR: 0.37; 95% CI: 0.17 to 0.78; p = 0.010), with no difference in device failure (9.2% vs. 6.2%; p = 0.742).
CONCLUSIONS
In patients with RBBB, risk of PPI was significantly lower with the NEO compared with the S3, suggesting the possibility of a patient tailored transcatheter heart valve therapy.