m+Medelevator.RU
← Поиск публикаций
International journal of cardiology · 2019

Outcomes of cardiac implantable electronic device transvenous lead extractions performed in centers without onsite cardiac surgery.

СтатьяМногоцентровое исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Mohamed Mohamed O, Greenspon Arnold, Contractor Tahmeed, Rashid Muhammad, Kwok Chun Shing, Potts Jessica, Barker Diane, Patwala Ashish, Mamas Mamas A

Аннотация

BACKGROUND: While major complications associated with CIED lead extractions are uncommon, they carry a significant risk of morbidity and mortality in the absence of surgical intervention. However, there is limited data on the differences in outcomes of these procedures between centers with and without on-site CS support. The present study examined outcomes of transvenous cardiac implantable electronic device (CIED) lead extractions according to admitting hospitals' cardiac surgery (CS) facilities.

METHODS: We analyzed the National Inpatient Sample for CIED lead extraction procedures, stratified by hospitals' CS facilities into two groups; on-site and off-site CS. Logistic regression analyses were performed to estimate the adjusted odds (aOR) of procedure-related complications in off-site CS centers.

RESULTS: In 221,606 procedures over an 11-year-period, CIED lead extractions were increasingly undertaken in on-site as opposed to off-site CS centers (Onsite CS 2004 vs. 2014: 78.2% vs. 90.4%, p < 0.001) during the study period. In comparison to on-site CS group, patients admitted to off-site CS group were older, less comorbid, and experienced lower adjusted odds of major adverse cardiovascular events (0.72 [0.67, 0.77]), mortality (0.60 [0.52, 0.69]), procedure-related bleeding (0.48 [0.44, 0.54]) and complications (thoracic: 0.81 [0.75, 0.88]; cardiac: 0.45 [0.38, 0.54]) (p < 0.001 for all).

CONCLUSIONS: Our national analysis demonstrates that transvenous CIED lead extractions are being increasingly undertaken in centers with on-site CS surgery, in compliance with international guideline recommendations. Patients managed with lead extractions in on-site CS centers are more comorbid and critically ill compared to those admitted to off-site CS centers, and remain at a higher risk of procedure-related complications.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты