MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ijcard.2019.07.061

Медицинская библиотека · International journal of cardiology · 2019

Public-access automated external defibrillator pad application and favorable neurological outcome after out-of-hospital cardiac arrest in public locations: A prospective population-based propensity score-matched study.

Kishimori Takefumi, Kiguchi Takeyuki, Kiyohara Kosuke, Matsuyama Tasuku, Shida Haruka, Nishiyama Chika, Kobayashi Daisuke, Okabayashi Satoe, Shimamoto Tomonari, Hayashida Sumito, Kitamura Tetsuhisa, Kawamura Takashi, Iwami Taku

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Randomized controlled trials or observational studies showed that the use of public-access automated external defibrillator (AED) was effective for patients with out-of-hospital cardiac arrest (OHCA). However, it is unclear whether public-access AED use is effective for all patients with OHCA irrespective of first documented rhythm. We aimed to evaluate the effect of public-access AED use for OHCA patients considering first documented rhythm (shockable or non-shockable) in public locations.

METHODS

From the Utstein-style registry in Osaka City, Japan, we obtained information on adult patients with OHCA of medical origin in public locations before emergency-medical-service personnel arrival between 2011 and 2015. Primary outcome was 1-month survival with favorable neurological outcome. Multivariable logistic regression analysis was performed to assess the association between the public-access AED pad application and favorable neurological outcome after OHCA by using one-to-one propensity score matching analysis.

RESULTS

Among 1743 eligible patients, a total of 336 (19.3%) patients received public-access AED pad application. The proportion of patients who survived 1-month with favorable neurological outcome was significantly higher in the pad application group than in the non-pad application group (29.8% vs. 9.7%; adjusted odds ratio [AOR], 2.85; 95% confidence interval [CI], 1.73-4.68, AOR after propensity score matching, 2.46; 95% CI, 1.29-4.68). In a subgroup analysis, the AORs of patients with shockable or non-shockable rhythms were 3.36 (95% CI, 1.78-6.35) and 2.38 (95% CI, 0.89-6.34), respectively.

CONCLUSIONS

Public-access AED pad application was associated with better outcome among patients with OHCA of medical origin in public locations irrespective of first documented rhythm.

Для цитирования: Kishimori Takefumi, Kiguchi Takeyuki, Kiyohara Kosuke, Matsuyama Tasuku, Shida Haruka, Nishiyama Chika, Kobayashi Daisuke, Okabayashi Satoe, Shimamoto Tomonari, Hayashida Sumito, Kitamura Tetsuhisa, Kawamura Takashi, Iwami Taku. Public-access automated external defibrillator pad application and favorable neurological outcome after out-of-hospital cardiac arrest in public locations: A prospective population-based propensity score-matched study.. International journal of cardiology. 2019. DOI: 10.1016/j.ijcard.2019.07.061.