MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ijcard.2019.04.022

Медицинская библиотека · International journal of cardiology · 2019

New-generation drug eluting stent vs. bare metal stent in saphenous vein graft - 1 year outcomes by a propensity score ascertainment (SVG Baltic Registry).

Wańha Wojciech, Mielczarek Maksymilian, Roleder Tomasz, Ładziński Szymon, Milewski Marek, Gilis-Malinowska Natasza, Chmielecki Michał, Ciećwierz Dariusz, Bachorski Witold, Kunik Piotr, Trznadel Agata, Męcka Klaudia, Genc Alicja, Januszek Rafał, Pączek Piotr, Dziewierz Artur, Bartuś Stanisław, Gruchała Marcin, Smolka Grzegorz, Dudek Dariusz, Navarese Eliano Pio, Ochała Andrzej, Jaguszewski Miłosz, Wojakowski Wojciech

Сравнительное исследованиеСтатьяМногоцентровое исследованиеПеревод в очереди

Аннотация

BACKGROUND

Data regarding the efficacy of the percutaneous coronary intervention (PCI) with new-designed drug-eluting stent (new-DES) vs. bare metal stent (BMS) of saphenous vein grafts (SVG) stenosis is scarce. The primary objective was to compare one-year clinical outcomes of PCI in stenosis of SVG using new-DES vs. BMS in a real-world population.

METHODS AND

RESULTS

We carried out a multi-center registry comparing new-DES with BMS in all consecutive patients undergoing PCI of SVG. The primary composite endpoint was major adverse cardiac and cerebrovascular events (MACCE) at 1 year. This observation included 792 consecutive patients (mean age 69 ± 8.9y), treated with either new-DES (n = 379, 47.9%) or BMS (n = 413, 52.1%). Among patients treated with new-DES compared with BMS, there was a lower risk of MACCE (21.4% vs. 28.3%, HR = 0.69, 95% CI 0.50-0.95, p = 0.025) as well as myocardial infarction (MI) (6.3% vs. 12.1%; HR 0.49, 95% CI 0.30-0.82, p = 0.005) at 1 year. After propensity score adjustment, the similar, significant reduction in MACCE and MI was observed in favor of new-DES (HR 0.66, 95% CI 0.46-0.96, p = 0.030; and HR 0.53, 95% CI 0.31-0.92, p = 0.020, respectively).

CONCLUSION

In patients undergoing PCI of SVG, the use of new-DES is associated with a reduced 1-year rate of MACCE and MI compared to BMS.

Для цитирования: Wańha Wojciech, Mielczarek Maksymilian, Roleder Tomasz, Ładziński Szymon, Milewski Marek, Gilis-Malinowska Natasza, Chmielecki Michał, Ciećwierz Dariusz, Bachorski Witold, Kunik Piotr, Trznadel Agata, Męcka Klaudia, Genc Alicja, Januszek Rafał, Pączek Piotr, Dziewierz Artur, Bartuś Stanisław, Gruchała Marcin, Smolka Grzegorz, Dudek Dariusz, Navarese Eliano Pio, Ochała Andrzej, Jaguszewski Miłosz, Wojakowski Wojciech. New-generation drug eluting stent vs. bare metal stent in saphenous vein graft - 1 year outcomes by a propensity score ascertainment (SVG Baltic Registry).. International journal of cardiology. 2019. DOI: 10.1016/j.ijcard.2019.04.022.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.