Predictors of rate-adaptive pacing in patients implanted with implantable cardioverter-defibrillator and subsequent differential clinical outcomes.

Källner Nils, Nishimura Marin, Birgersdotter-Green Ulrika, Hoffmayer Kurt S, Han Frederick T, Krummen David E, Raissi Farshad, Feld Gregory K, Hsu Jonathan C

СтатьяПеревод в очереди

Аннотация

PURPOSE: Patients with severe cardiomyopathy often have chronotropic incompetence, which is predominantly managed by activating rate-adaptive pacing in patients implanted with an implantable cardioverter-defibrillator (ICD) capable of atrial pacing. The purpose of this study was to determine predictors of rate-adaptive pacing activation, the cumulative incidence of activation, and the association of rate-adaptive pacing activation with subsequent clinical outcomes in an ICD population.

METHODS

The authors evaluated 228 patients implanted with an ICD between 2011 and 2015. Multivariable logistic regression was used to evaluate predictors of rate-adaptive pacing activation. Cox proportional-hazards regression was used to examine associations of rate-adaptive pacing activation and clinical outcomes.

RESULTS

Rate-adaptive pacing was turned on in 38.5% (n = 88) of patients during follow-up. Several statistically significant predictors of rate-adaptive pacing activation were found, particularly previous atrial fibrillation (odds ratio [OR] = 8.27, 95% confidence interval [CI] = 2.96-23.06, p < 0.001), previous myocardial infarction (OR = 4.17, 95% CI = 1.38-12.58, p = 0.01), and non-ischemic cardiomyopathy (OR = 3.83, 95% CI = 1.22-12.00, p = 0.02). In multivariable adjusted analyses, rate-adaptive pacing activation within 30 days of implantation was not associated with the risk of device therapy for tachyarrhythmias (hazard ratio [HR] = 1.52, 95% CI = 0.71-3.28, p = 0.29), atrial fibrillation (HR = 1.42, 95% CI = 0.71-2.87, p = 0.32), HF re-admission (HR = 1.39, 95% CI = 0.80-2.43, p = 0.25), nor all-cause mortality (HR = 2.34, 95% CI = 0.80-6.84, p = 0.12).

CONCLUSIONS

During follow-up, more than one in three HF patients implanted with an ICD developed the need for rate-adaptive pacing. Atrial fibrillation, prior myocardial infarction, and non-ischemic cardiomyopathy were statistically significant baseline clinical predictors of rate-adaptive pacing activation. Rate-adaptive pacing activation was not associated with subsequent adverse clinical outcomes.

Для цитирования: Källner Nils, Nishimura Marin, Birgersdotter-Green Ulrika, Hoffmayer Kurt S, Han Frederick T, Krummen David E, Raissi Farshad, Feld Gregory K, Hsu Jonathan C. Predictors of rate-adaptive pacing in patients implanted with implantable cardioverter-defibrillator and subsequent differential clinical outcomes.. Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing. 2019. DOI: 10.1007/s10840-019-00536-9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.