OBJECTIVE

Data on the comparative effectiveness of contemporary drug-eluting stents (DES) in the unrestricted, real-world setting are limited. We investigated the long-term effectiveness and safety of contemporary different drug-eluting stents by means of multiple treatment propensity score weighting.

PATIENTS AND

METHODS

From seven stent-specific, prospective DES registries conducted between July 2007 and July 2015, we evaluated 17 196 patients who received several contemporary DES and first-generation DES: 3053 treated with cobalt-chromium everolimus-eluting stents (CoCr-EES), 2985 with platinum-chromium EES (PtCr-EES), 2922 with Resolute zotarolimus-eluting stents (Re-ZES), 789 with Biomatrix biolimus-eluting stents (Bi-BES), 1907 with Nobori biolimus-eluting stents (No-BES), 1970 with Xience Prime cobalt-chromium everolimus-eluting stents (Pr-CoCr-EES), and 3570 with sirolimus-eluting stents (SES). The primary outcome was target-vessel failure (a composite of cardiac death, target-vessel myocardial infarction, or target-vessel revascularization) at 3 years of follow-up and major cardiovascular adverse events (a composite of all-cause death, any myocardial infarction, or any revascularization) was also evaluated.

RESULTS

The observed 3-year rates of target-vessel failure were not significantly different among different second-generation DES and SES (CoCr-EES 9.8%, PtCr-EES 9.5%, Re-ZES 9.3%, Bi-BES 9.8%, No-BES 7.7%, Pr-CoCr-EES 10.4%, SES 10.2%; overall P=0.07). In multiple treatment propensity score analysis, adjusted hazard ratios for target-vessel failure were similar in between-group comparisons of several contemporary DES. In addition, no significant differences were observed with respect of the adjusted risk of major adverse cardiac events.

CONCLUSION

In this comparative effectiveness research using stent-specific, clinical practice registries involving unrestricted use of several contemporary DES, there were no significant between-group differences in the 3-year rates of target-vessel failure.

Для цитирования: Kwon Osung, Kang Se Hun, Lee Jung-Bok, Ahn Jung-Min, Lee Cheol Hyun, Kang Do-Yoon, Lee Pil Hyung, Kang Soo-Jin, Lee Seung-Whan, Kim Young-Hak, Lee Cheol Whan, Park Seong-Wook, Park Duk-Woo, Park Seung-Jung, IRIS-DES Registry Investigators. Comparative effectiveness of different contemporary drug-eluting stents in routine clinical practice: a multigroup propensity score analysis using data from the stent-specific, multicenter, prospective registries.. Coronary artery disease. 2019. DOI: 10.1097/mca.0000000000000730.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.