Circulation. Cardiovascular interventions · 2018
Relationship Between Intravascular Ultrasound Guidance and Clinical Outcomes After Drug-Eluting Stents.
СтатьяМногоцентровое исследованиеПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Maehara Akiko, Mintz Gary S, Witzenbichler Bernhard, Weisz Giora, Neumann Franz-Josef, Rinaldi Michael J, Metzger D Christopher, Henry Timothy D, Cox David A, Duffy Peter L, Brodie Bruce R, Stuckey Thomas D, Mazzaferri Ernest L, McAndrew Thomas, Généreux Philippe, Mehran Roxana, Kirtane Ajay J, Stone Gregg W
Аннотация
Background In the large-scale ADAPT-DES study (Assessment of Dual Antiplatelet Therapy With Drug-Eluting Stents), drug-eluting stent implantation with intravascular ultrasound (IVUS) guidance was associated with a reduction in 1-year rates of stent thrombosis, myocardial infarction (MI), and major adverse cardiac events (cardiac death, MI, or stent thrombosis) compared with angiography guidance alone. We assessed whether the benefits of IVUS guidance were maintained, reduced, or increased at 2 years. Methods and Results ADAPT-DES was a prospective, multicenter, nonrandomized all-comers study of 8582 consecutive patients at 11 US and German sites designed to determine the frequency, timing, and correlates of adverse events after drug-eluting stents. Propensity-adjusted multivariable analysis was performed to examine the impact of IVUS guidance on 2-year outcomes. IVUS guidance (n=3361; 39%) compared with angiography guidance (n=5221; 61%) was associated with reduced 2-year adjudicated rates of (1) major adverse cardiac events (cardiac death, MI, or stent thrombosis; 4.9% versus 7.5%; adjusted hazard ratio, 0.72; 95% CI, 0.59-0.89; P=0.003), (2) definite/probable stent thrombosis (0.55% versus 1.16%; adjusted hazard ratio, 0.40; 95% CI, 0.22-0.73; P=0.003), and (3) MI (3.5% versus 5.6%; adjusted hazard ratio, 0.65; 95% CI, 0.51-0.83; P=0.0006). By landmark analysis, IVUS guidance compared with angiography guidance was also associated with significantly reduced rates of major adverse cardiac events, MI, stent thrombosis, and clinically driven target lesion revascularization between 1 and 2 years after drug-eluting stent implantation. The number needed to treat with IVUS guidance to prevent 1 major adverse cardiac event was reduced from 64 (42-137) at 1 year to 41 (29-69) at 2 years. Conclusions In ADAPT-DES, the early improvement in event-free survival after drug-eluting stent implantation with IVUS guidance compared with angiography guidance was further increased with longer term follow-up to 2 years. Clinical Trial Registration URL: https://www.clinicaltrials.gov . Unique identifier: NCT00638794.
Предметные рубрики MeSH
AgedAnatomic LandmarksCoronary AngiographyCoronary DiseaseCoronary ThrombosisDrug-Eluting StentsFemaleGermanyHumansMaleMiddle AgedPercutaneous Coronary InterventionPredictive Value of TestsProgression-Free SurvivalProspective StudiesRadiography, InterventionalRecurrenceRegistriesRisk AssessmentRisk FactorsTime FactorsUltrasonography, InterventionalUnited States