m+Medelevator.RU
← Поиск публикаций
Journal of the American College of Cardiology · 2018

Prosthesis-Patient Mismatch in Patients Undergoing Transcatheter Aortic Valve Replacement: From the STS/ACC TVT Registry.

СтатьяНаблюдательное исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Herrmann Howard C, Daneshvar Samuel A, Fonarow Gregg C, Stebbins Amanda, Vemulapalli Sreekanth, Desai Nimesh D, Malenka David J, Thourani Vinod H, Rymer Jennifer, Kosinski Andrzej S

Аннотация

BACKGROUND: Prosthesis-patient mismatch (PPM) after surgical aortic valve replacement (AVR) for aortic stenosis is generally associated with worse outcomes. Transcatheter AVR (TAVR) can achieve a larger valve orifice and the effects of PPM after TAVR are less well studied.

OBJECTIVES: The authors utilized the Society of Thoracic Surgeons/American College of Cardiology TVT (Transcatheter Valve Therapy) registry to examine the frequency, predictors, and association with outcomes of PPM after TAVR in 62,125 patients enrolled between 2014 and 2017.

METHODS: On the basis of the discharge echocardiographic effective valve area indexed to body surface area, PPM was classified as severe (<0.65 cm2/m2), moderate (0.65 to 0.85 cm2/m2), or none (>0.85 cm2/m2). Multivariable regression models were utilized to examine predictors of severe PPM as well as adjusted outcomes, including mortality, heart failure (HF) rehospitalization, stroke, and quality of life, at 1 year in 37,470 Medicare patients with claims linkage.

RESULTS: Severe and moderate PPM were present following TAVR in 12% and 25% of patients, respectively. Predictors of severe PPM included small (≤23-mm diameter) valve prosthesis, valve-in-valve procedure, larger body surface area, female sex, younger age, non-white/Hispanic race, lower ejection fraction, atrial fibrillation, and severe mitral or tricuspid regurgitation. At 1 year, mortality was 17.2%, 15.6%, and 15.9% in severe, moderate, and no PPM patients, respectively (p = 0.02). HF rehospitalization had occurred in 14.7%, 12.8%, and 11.9% of patients with severe, moderate, and no PPM, respectively (p < 0.0001). There was no association of severe PPM with stroke or quality-of-life score at 1 year.

CONCLUSIONS: Severe PPM after TAVR was present in 12% of patients and was associated with higher mortality and HF rehospitalization at 1 year. Further investigation is warranted into the prevention of severe PPM in patients undergoing TAVR.