MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jacc.2018.04.074

Медицинская библиотека · Journal of the American College of Cardiology · 2018

Transcatheter Aortic Valve Replacement of Failed Surgically Implanted Bioprostheses: The STS/ACC Registry.

Tuzcu E Murat, Kapadia Samir R, Vemulapalli Sreekanth, Carroll John D, Holmes David R, Mack Michael J, Thourani Vinod H, Grover Frederick L, Brennan J Matthew, Suri Rakesh M, Dai David, Svensson Lars G

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Valve-in-valve (ViV) transcatheter aortic valve replacement (TAVR) has been shown to be feasible, yet the safety and efficacy in relation to native valve (NV) TAVR are not known.

OBJECTIVES

This study sought to evaluate the safety and effectiveness of ViV TAVR for failed surgical aortic valve replacement (SAVR) by comparing it with the benchmark of NV TAVR.

METHODS

Patients who underwent ViV-TAVR (n = 1,150) were matched 1:2 (on sex, high or extreme risk, hostile chest or porcelain aorta, 5-m-walk time, and Society of Thoracic Surgeons Predicted Risk of Mortality for reoperation) to patients undergoing NV-TAVR (n = 2,259). Baseline characteristics, procedural data, and in-hospital outcomes were obtained from the Transcatheter Valve Therapy Registry. The 30-day and 1-year outcomes were obtained from linked Medicare administrative claims data.

RESULTS

Unadjusted analysis revealed lower 30-day mortality (2.9% vs. 4.8%; p < 0.001), stroke (1.7% vs. 3.0%; p = 0.003), and heart failure hospitalizations (2.4% vs. 4.6%; p < 0.001) in the ViV-TAVR compared with NV-TAVR group. Adjusted analysis revealed lower 30-day mortality (hazard ratio: 0.503; 95% confidence interval: 0.302 to 0.839; p = 0.008), lower 1-year mortality (hazard ratio: 0.653; 95% confidence interval: 0.505 to 0.844; p = 0.001), and hospitalization for heart failure (hazard ratio: 0.685; 95% confidence interval: 0.500 to 0.939; p = 0.019) in the ViV-TAVR group. Patients in the ViV-TAVR group had higher post-TAVR mean gradient (16 vs. 9 mm Hg; p < 0.001), but less moderate or severe aortic regurgitation (3.5% vs. 6.6%; p < 0.001). Post-TAVR gradients were highest in small SAVRs and stenotic SAVRs.

CONCLUSIONS

Comparison with the benchmark NV-TAVR shows ViV-TAVR to be a safe and effective procedure in patients with failed SAVR who are at high risk for repeat surgery.

Для цитирования: Tuzcu E Murat, Kapadia Samir R, Vemulapalli Sreekanth, Carroll John D, Holmes David R, Mack Michael J, Thourani Vinod H, Grover Frederick L, Brennan J Matthew, Suri Rakesh M, Dai David, Svensson Lars G. Transcatheter Aortic Valve Replacement of Failed Surgically Implanted Bioprostheses: The STS/ACC Registry.. Journal of the American College of Cardiology. 2018. DOI: 10.1016/j.jacc.2018.04.074.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.