m+Medelevator.RU
← Поиск публикаций
Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2018

Comparison of devices used in carotid artery stenting: A vascular quality initiative analysis of commonly used carotid stents and embolic protection devices.

Сравнительное исследованиеСтатьяНаблюдательное исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Dhillon Ashwat S, Li Sisi, Lewinger Juan Pablo, Shavelle David M, Matthews Ray V, Clavijo Leonardo C, Weaver Fred A, Garg Parveen

Аннотация

BACKGROUND: Data regarding efficacy of various stent and embolic protection device (EPD) combinations to prevent stroke during carotid artery stenting (CAS) is limited. We compared post-procedure inpatient neurologic outcomes across various carotid stent-EPD platforms recorded in the Vascular Quality Initiative (VQI) registry.

METHODS: We analyzed 13,786 consecutive CAS procedures in the VQI registry performed between January 1, 2005 and December 31, 2015. The most commonly used stent-EPD combinations (n = 5407) were included in the analysis. Post-procedure inpatient neurologic outcomes included (1) ipsilateral stroke/transient ischemic attack (TIA) and (2) any stroke/TIA. Multivariate generalized estimating equation regression analysis was performed, adjusting for age, sex, tobacco use, coronary artery disease, congestive heart failure, prior stroke/TIA, hypertension, history of carotid revascularization, and presence of a second ipsilateral stenosis >70%, to determine whether risk of outcomes differed according to device.

RESULTS: Of 13,786 CAS procedures, Xact-Emboshield (n = 2,438, 17.6%), Precise-Angioguard (n = 1,480, 10.7%), Acculink-Accunet (n = 829, 6.01%), and Acculink-Emboshield (n = 660, 4.8%) were the most commonly used combinations, accounting for a total of 5,407 procedures. Inpatient event rates for ipsilateral stroke/TIA and any stroke/TIA were 1.9 and 2.7% in the Accunet-Acculink, 3.0 and 3.2% in Acculink-Emboshield, 3.2 and 4.1% in Precise-Angioguard and 2.2 and 3.0% in Xact-Emboshield. There was no evidence of difference in risk of ipsilateral stroke/TIA or any stroke/TIA across device combinations (P = 0.15 and P = 0.16, respectively).

CONCLUSION: CAS with current carotid stent-EPD combinations is associated with low rates of inpatient stroke/TIA. There is no statistically significant difference in rates of inpatient stroke/TIA across device combinations.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты