Circulation journal : official journal of the Japanese Circulation Society · 2017
Survival and Heart Failure Hospitalization in Patients With Cardiac Resynchronization Therapy With or Without a Defibrillator for Primary Prevention in Japan - Analysis of the Japan Cardiac Device Treatment Registry Database.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Yokoshiki Hisashi, Shimizu Akihiko, Mitsuhashi Takeshi, Furushima Hiroshi, Sekiguchi Yukio, Manaka Tetsuyuki, Nishii Nobuhiro, Ueyama Takeshi, Morita Norishige, Okamura Hideo, Nitta Takashi, Hirao Kenzo, Okumura Ken, Members of the Implantable Cardioverter-Defibrillator (ICD) Committee of the Japanese Heart Rhythm Society
Аннотация
BACKGROUND: Randomized control trials comparing the effectiveness of cardiac resynchronization therapy devices, with (CRT-D) or without (CRT-P) a defibrillator, are scarce in heart failure patients with no prior sustained ventricular tachyarrhythmias.
METHODS AND RESULTS: The Japan Cardiac Device Treatment Registry (JCDTR) has data for 2714 CRT-D and 555 CRT-P recipients for primary prevention with an implantation date between January 2011 and August 2015. Of these patients, follow-up data were available for 717. Over the mean follow-up period of 21 months, Kaplan-Meier curves of survival free of combined events for all-cause death or heart failure hospitalization (whichever came first) diverged between the CRT-D (n=620) and CRT-P (n=97) groups with a rate of 22% vs. 42%, respectively, at 24 months (P=0.0011). However, this apparent benefit of CRT-D over CRT-P was no longer significant after adjustment for covariates. With regard to mortality, including heart failure death or sudden cardiac death, there was no significant difference between the 2 groups.
CONCLUSIONS: In patients without sustained ventricular tachyarrhythmias enrolled in the JCDTR, there was no significant difference in mortality between the CRT-D and CRT-P groups, despite a lower trend in CRT-D recipients. This study was limited by large clinical and demographic differences between the 2 groups.
METHODS AND RESULTS: The Japan Cardiac Device Treatment Registry (JCDTR) has data for 2714 CRT-D and 555 CRT-P recipients for primary prevention with an implantation date between January 2011 and August 2015. Of these patients, follow-up data were available for 717. Over the mean follow-up period of 21 months, Kaplan-Meier curves of survival free of combined events for all-cause death or heart failure hospitalization (whichever came first) diverged between the CRT-D (n=620) and CRT-P (n=97) groups with a rate of 22% vs. 42%, respectively, at 24 months (P=0.0011). However, this apparent benefit of CRT-D over CRT-P was no longer significant after adjustment for covariates. With regard to mortality, including heart failure death or sudden cardiac death, there was no significant difference between the 2 groups.
CONCLUSIONS: In patients without sustained ventricular tachyarrhythmias enrolled in the JCDTR, there was no significant difference in mortality between the CRT-D and CRT-P groups, despite a lower trend in CRT-D recipients. This study was limited by large clinical and demographic differences between the 2 groups.