MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.hlc.2016.11.015

Медицинская библиотека · Heart, lung & circulation · 2016

Single-Centre Experience of Off-Pump Multi-Vessel Coronary Artery Bypass Grafting Using Proximal Suture Device.

Ohira Suguru, Doi Kiyoshi, Numata Satoshi, Yamazaki Sachiko, Itatani Keiichi, Kawajiri Hidetake, Morimoto Kazuki, Yaku Hitoshi

СтатьяПеревод в очереди

Аннотация

BACKGROUND

To investigate the results of off-pump coronary artery grafting (OPCAB) with the proximal suture device (PSD) regarding postoperative stroke and graft patency.

METHODS

The PSD was used in 376 patients (32.0%), aorta-no-touch OPCAB was performed in 523 patients (45.2%), on-pump beating coronary artery bypass surgery (CABG) (on-beat group) in 125 patients (10.6%) including 51 conversions (conversion rate: 5.4%), and CABG with aortic clamp use (clamp group) in 152 patients. In the PSD group, Enclose II was used in 267 patients (71.0%).

RESULTS

The hospital mortality rate was 1.95%. There was no early stroke in the OPCAB group, whereas the early-stroke rate was 0.8% in the on-beat group and 2.6% in the clamp group. The incidences of stroke at one month were: PSD group, 1.6%; no-touch group, 1.1%; on-beat group, 1.6%; and clamp group, 4.6% (p=0.014). The rates of complete revascularisation were higher in the PSD and clamp groups (94.7 and 94.0%, respectively) compared with the no-touch and on-beat groups (81.5 and 84.9%, respectively; p<0.001). The vein graft patency rates were comparable between the PSD and clamp groups. In multiple logistic regression analysis, OPCAB using the PSD did not increase the risk of stroke compared with the no-touch group (adjusted odds ratio [AOR]: 1.40; p=0.594) or on-beat group (AOR: 0.99; p=0.206), but reduced the risk of stroke compared with the clamp group (AOR: 0.19; p=0.005).

CONCLUSIONS

Off-pump coronary artery grafting using the PSD was a safe and effective procedure. It led to lower incidences of postoperative stroke and excellent rates of graft patency and complete revascularisation compared with conventional CABG.

Для цитирования: Ohira Suguru, Doi Kiyoshi, Numata Satoshi, Yamazaki Sachiko, Itatani Keiichi, Kawajiri Hidetake, Morimoto Kazuki, Yaku Hitoshi. Single-Centre Experience of Off-Pump Multi-Vessel Coronary Artery Bypass Grafting Using Proximal Suture Device.. Heart, lung & circulation. 2016. DOI: 10.1016/j.hlc.2016.11.015.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.