International journal of cardiology · 2016
Device-related infective endocarditis in cardiac resynchronization therapy recipients - Single center registry with over 2500 person-years follow up.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Jędrzejczyk-Patej Ewa, Mazurek Michał, Kowalski Oskar, Sokal Adam, Kozieł Monika, Adamczyk Karolina, Przybylska-Siedlecka Katarzyna, Morawski Stanisław, Liberska Agnieszka, Szulik Mariola, Podolecki Tomasz, Kowalczyk Jacek, Kalarus Zbigniew, Lenarczyk Radosław
Аннотация
AIM: To assess incidence, predisposing factors and outcomes of cardiac device-related infective endocarditis (CDRIE) in patients undergoing cardiac resynchronization therapy (CRT).
METHODS AND RESULTS: High-volume, single-center cardiology database was screened to identify all CDRIE cases, based on modified Duke criteria, amongst 765 consecutive CRT implantations between 2002 and 2015 (70.8% de novo implantations, 13.7% and 15.5% up-grades from pacemaker and implantable cardioverter–defibrillator [ICD], respectively). During the median follow-up (FU) of 1207 days (range: 256–2664) overall 38 CDRIE (4.97%) cases were identified (incidence: 15/1000 person-years). Multivariate Cox regression model, incorporating significant baseline differences as covariates (model 1), demonstrated that both up-grade from ICD to CRT and higher baseline NYHA class were independently associated with increased risk of CDRIE (adjusted HR 4.29, 95%CI 1.93–9.57; and HR 2.43, 95%CI 1.32–4.49, respectively). In the second model (including all differences with P < 0.2) up-grade from ICD (HR 4.36, 95%CI 1.96–9.69), higher NYHA class (HR 2.04, 95%CI 1.11–3.75), hypertrophic cardiomyopathy (HR 5.85, 95% CI 1.46–23.52), lower baseline hemoglobin level (HR 0.68, 95%CI 0.50–0.94) and chronic obstructive pulmonary disease (HR 2.46, 95%CI 1.05–5.77) were all independently associated with higher risk of CDRIE. All-cause mortality in patients with CDRIE was significantly higher than in subjects without infective complications (68.4% vs. 33.7%, P < 0.001), and 50% of patients with CDRIE died during index hospitalization.
CONCLUSIONS: The prevalence of CDRIE in CRT recipients is almost 5% within 3.5 years post implantation. Up-grade from ICD and high baseline NYHA class flag up patients at high-risk of CDRIE. CRT-related infective complications are associated with very poor prognosis.
METHODS AND RESULTS: High-volume, single-center cardiology database was screened to identify all CDRIE cases, based on modified Duke criteria, amongst 765 consecutive CRT implantations between 2002 and 2015 (70.8% de novo implantations, 13.7% and 15.5% up-grades from pacemaker and implantable cardioverter–defibrillator [ICD], respectively). During the median follow-up (FU) of 1207 days (range: 256–2664) overall 38 CDRIE (4.97%) cases were identified (incidence: 15/1000 person-years). Multivariate Cox regression model, incorporating significant baseline differences as covariates (model 1), demonstrated that both up-grade from ICD to CRT and higher baseline NYHA class were independently associated with increased risk of CDRIE (adjusted HR 4.29, 95%CI 1.93–9.57; and HR 2.43, 95%CI 1.32–4.49, respectively). In the second model (including all differences with P < 0.2) up-grade from ICD (HR 4.36, 95%CI 1.96–9.69), higher NYHA class (HR 2.04, 95%CI 1.11–3.75), hypertrophic cardiomyopathy (HR 5.85, 95% CI 1.46–23.52), lower baseline hemoglobin level (HR 0.68, 95%CI 0.50–0.94) and chronic obstructive pulmonary disease (HR 2.46, 95%CI 1.05–5.77) were all independently associated with higher risk of CDRIE. All-cause mortality in patients with CDRIE was significantly higher than in subjects without infective complications (68.4% vs. 33.7%, P < 0.001), and 50% of patients with CDRIE died during index hospitalization.