m+Medelevator.RU
← Поиск публикаций
Vojnosanitetski pregled · 2016

Percutaneous implantation of self-expandable aortic valve in high risk patients with severe aortic stenosis: The first experiences in Serbia.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Nedeljković Milan A, Beleslin Branko, Tesić Milorad, Vukcević Vladan, Stanković Goran, Stojković Sinisa, Orlić Dejan, Bilbija Ilija, Matković Milos, Simić Tijana, Menković Nemanja, Mrdović Igor, Ussia Gian Paolo, Perisić Zoran, Babić Momcilo

Аннотация

BACKGROUND/AIM: Aortic stenosis (AS) is the most common valvular heart disease in elderly people, with rather poor prognosis in symptomatic patients. Surgical valve replacement is the therapy of choice, but a significant number of patients cannot undergo surgical procedure. We presented initial experience of transcatheter aortic valve implantation (TAVI) performed in Catheterization Laboratory of the Clinic for Cardiology, Clinical Center of Serbia.

METHODS: The procedures were performed in 5 patients (mean age 76 ± 6 years, 2 males, 3 female) with severe and symptomatic AS with contraindication to surgery or high surgical risk. The decision to perform TAVI was made by the heart team. Pre-procedure screening included detailed clinical and echocardiographic evaluation, coronary angiography and computed tomography scan. In all the patients we implanted a self-expandable aortic valve (Core Valve, Medtronic, USA). Six months follow-up was available for all the patients.

RESULTS: All interventions were successfully performed without significant periprocedural complications. Immediate hemodynamic improvement was obtained in all the patients (peak gradient 94.2 ± 27.6 to 17.6 ± 5.2 mmHg, p < 0.001, mean pressure gradient 52.8 ± 14.5 to 8.0 ± 2.1 mmHg, p < 0.001). None of the patients developed heart block, stroke, vascular complication or significant aortic regurgitation. After 6 months, the survival was 100% with New York Heart Association (NYHA) functional improvement in all the patients.

CONCLUSION: This successful initial experience provides a solid basis to treat larger number of patients with symptomatic AS and high surgical risk who are left untreated.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты