m+Medelevator.RU
← Поиск публикаций
Physics in medicine and biology · 2026

Influence of scintillation light confinement on depth-of-interaction measurement performance in a single-ended readout PET detector.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Shim Hyeong Seok, Cho Min Jeong, He Wen, Lee Min Sun, Levin Craig S, Lee Jae Sung

Аннотация

Continuous depth-of-interaction (cDOI) detectors enable single-ended readout in positron emission tomography (PET) by encoding the interaction depth into the scintillation light distribution. This study presents a comprehensive performance optimization of a cDOI detector based on light distribution tailoring with crossed triangular-shaped reflectors by analyzing the effects of optical geometry based on various DOI decoding algorithms. Two parameters were systematically varied: the degree of light confinement through (1) optical segmentation and (2) crystal pitch adjustment. Five DOI decoding strategies-variance, max/sum ratio, Euclidean-distance classification, Gaussian and modified maximum-likelihood estimation, and artificial neural network (ANN) decoding-were adopted with 8 × 8 SiPM readout data. Results show that moderate segmentation (2 × 2 configuration) achieved the best DOI precision, yielding a 4.7 mm full width at half maximum (FWHM) and an ANN classification accuracy of 89 %. In the pitch study, 1.5 mm-pitch detector achieved better performance than 3.0 mm-pitch, indicating that increased optical interfaces allows more accurate encoding of the depth-dependent light distribution within the SiPM array. The ANN decoder consistently outperformed in DOI resolution compared to analytical and statistical methods by learning nonlinear spatial correlations among SiPM pixels. These findings highlight the coupled importance of optical geometry and data-driven decoding for achieving high DOI sensitivity in next-generation PET detector designs.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты