DOI 10.1097/mat.0000000000000297

Медицинская библиотека · ASAIO journal (American Society for Artificial Internal Organs : 1992) · 2016

Surgical Considerations and Challenges for Bilateral Continuous-Flow Durable Device Implantation.

Maltais Simon, Womack Sara, Davis Mary E, Danter Matthew R, Kushwaha Sudhir S, Stulak John M, Haglund Nicholas

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

The concept of biventricular support with durable centrifugal pumps is evolving, and the surgical strategy and best practice guidelines for implantation of right-sided devices are still unknown. We present optimal strategy for bilateral HeartWare continuous-flow ventricular assist device (HVAD) implantation in a series of four patients. Patients were implanted with the HVAD pumps simultaneously or sequentially. This report offers a perspective on surgical considerations such as right ventricular positioning, implications related to potential risks of obstruction from the tricuspid apparatus, the role if any of downsizing the outflow anastomosis, and considerations for speed adjustments. In this series, one patient died on support and three patients experienced pump thrombosis requiring device revision. All other patients survived until orthotopic heart transplantation, although one of these patients died from perioperative complications, 2 days posttransplantation. Surgical management of patients with medically refractory biventricular heart failure remains challenging and associated with a high incidence of pump thrombosis. Best practice guidelines from experts' consensus are still needed to address this challenging population.

Для цитирования: Maltais Simon, Womack Sara, Davis Mary E, Danter Matthew R, Kushwaha Sudhir S, Stulak John M, Haglund Nicholas. Surgical Considerations and Challenges for Bilateral Continuous-Flow Durable Device Implantation.. ASAIO journal (American Society for Artificial Internal Organs : 1992). 2016. DOI: 10.1097/mat.0000000000000297.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.