MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s10840-015-9983-6

Медицинская библиотека · Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing · 2015

Ambulatory respiratory rate trends identify patients at higher risk of worsening heart failure in implantable cardioverter defibrillator and biventricular device recipients: a novel ambulatory parameter to optimize heart failure management.

Goetze Stephan, Zhang Yi, An Qi, Averina Viktoria, Lambiase Pier, Schilling Richard, Trappe Hans-Joachim, Winter Siegmund, Wold Nicholas, Manola Ljubomir, Kestens Dries

Контролируемое клиническое исследованиеСтатьяМногоцентровое исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: Respiratory distress is the primary driver for heart failure (HF) hospitalization. Implantable pacemakers and defibrillators are capable of monitoring respiratory rate (RR) in ambulatory HF patients. We investigated changes in RR prior to HF hospitalizations and its near-term risk stratification power.

METHODS

NOTICE-HF was an international multi-center study. Patients were implanted with an implantable cardioverter defibrillator or cardiac resynchronization therapy defibrillator, capable of trending daily maximum, median, and minimum RR (maxRR, medRR, minRR). RR from 120 patients with 9 months of follow-up was analyzed. One-tailed Student's t test was used to compare RR values prior to HF events to baseline defined as 4 weeks prior to the events. A Cox regression model was used to calculate the hazard ratios (HR) for the 30-day HF hospitalization risk based on RR values in the preceding month.

RESULTS

Daily maxRR, medRR, and minRR were significantly elevated prior to HF events compared to baseline (ΔmaxRR 1.8 ± 3.0; p = 0.02; ΔmedRR, 2.1 ± 2.8; p = 0.007; ΔminRR, 1.5 ± 2.1, p = 0.008). Risk of experiencing HF events within 30-days was increased if the standard deviation of medRR over the preceding month was above 1.0 br/min (HR = 12.3, 95 % confidence interval (CI) 2.57-59, p = 0.002). The risk remained high after adjusting for clinical variables that differed at enrollment.

CONCLUSION

Ambulatory daily respiratory rate trends may be a valuable addition to standard management for HF patients.

Для цитирования: Goetze Stephan, Zhang Yi, An Qi, Averina Viktoria, Lambiase Pier, Schilling Richard, Trappe Hans-Joachim, Winter Siegmund, Wold Nicholas, Manola Ljubomir, Kestens Dries. Ambulatory respiratory rate trends identify patients at higher risk of worsening heart failure in implantable cardioverter defibrillator and biventricular device recipients: a novel ambulatory parameter to optimize heart failure management.. Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing. 2015. DOI: 10.1007/s10840-015-9983-6.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.