MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ijcard.2014.08.049

Медицинская библиотека · International journal of cardiology · 2014

One-year clinical outcomes of everolimus- versus sirolimus-eluting stents in patients with acute myocardial infarction.

Chen Kang-Yin, Rha Seung-Woon, Wang Lin, Li Yong-Jian, Li Guang-Ping, Choi Cheol Ung, Park Chang Gyu, Seo Hong Seog, Oh Dong Joo, Jeong Myung Ho, Ahn Young Keun, Hong Taek Jong, Kim Young Jo, Chae Shung Chull, Hur Seung Ho, Seong In Whan, Chae Jei Keon, Cho Myeong Chan, Bae Jang Ho, Choi Dong Hoon, Jang Yang Soo, Chae In Ho, Kim Hyo Soo, Kim Chong Jin, Yoon Jung Han, Ahn Tae Hoon, Chung Wook Sung, Seung Ki Bae, Park Seung Jung, Korea Acute Myocardial Infarction Registry Investigators

Сравнительное исследованиеСтатьяМногоцентровое исследованиеПеревод в очереди

Аннотация

BACKGROUND

In contrast to many studies comparing everolimus-eluting stent (EES) with paclitaxel-eluting stent (PES), data directly comparing EES with sirolimus-eluting stent (SES) are limited, especially in patients with acute myocardial infarction (AMI).

METHODS

This study includes 2911 AMI patients treated with SES (n=1264) or EES (n=1701) in Korea Acute Myocardial Infarction Registry (KAMIR). Propensity score matching was applied to adjust for baseline imbalance in clinical and angiographic characteristics, yielding a total of 2400 well-matched patients (1200 receiving SES and 1200 receiving EES). One-year clinical outcomes were compared between the two propensity score matched groups.

RESULTS

Baseline clinical and angiographic characteristics were similar between the two propensity score matched groups. One-year clinical outcomes of the propensity score matched cohort were comparable between the EES versus the SES groups including the rates of cardiac death (4.8% vs. 4.8%, P=1.000), recurrent myocardial infarction (1.4% vs. 1.7%, P=0.619), target lesion revascularization (1.4% vs. 1.6%, P=0.737), target lesion failure (7.0% vs. 7.3%, P=0.752), and probable or definite stent thrombosis (0.5% vs. 0.9%, P=0.224) except for a trend toward lower incidence of target vessel revascularization (1.9% vs. 3.0%, P=0.087) and a lower rate of total major adverse cardiac events (9.3% vs. 11.9%, P=0.034) in the EES group.

CONCLUSIONS

The present propensity score matched analysis performed in a large-scale, prospective, multicenter registry suggests that the second-generation drug-eluting stent EES has at least comparable or even better safety and efficacy profiles as compared with SES in the setting of AMI.

Для цитирования: Chen Kang-Yin, Rha Seung-Woon, Wang Lin, Li Yong-Jian, Li Guang-Ping, Choi Cheol Ung, Park Chang Gyu, Seo Hong Seog, Oh Dong Joo, Jeong Myung Ho, Ahn Young Keun, Hong Taek Jong, Kim Young Jo, Chae Shung Chull, Hur Seung Ho, Seong In Whan, Chae Jei Keon, Cho Myeong Chan, Bae Jang Ho, Choi Dong Hoon, Jang Yang Soo, Chae In Ho, Kim Hyo Soo, Kim Chong Jin, Yoon Jung Han, Ahn Tae Hoon, Chung Wook Sung, Seung Ki Bae, Park Seung Jung, Korea Acute Myocardial Infarction Registry Investigators. One-year clinical outcomes of everolimus- versus sirolimus-eluting stents in patients with acute myocardial infarction.. International journal of cardiology. 2014. DOI: 10.1016/j.ijcard.2014.08.049.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.