MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1161/circep.113.001705

Медицинская библиотека · Circulation. Arrhythmia and electrophysiology · 2014

Protein biomarkers identify patients unlikely to benefit from primary prevention implantable cardioverter defibrillators: findings from the Prospective Observational Study of Implantable Cardioverter Defibrillators (PROSE-ICD).

Cheng Alan, Zhang Yiyi, Blasco-Colmenares Elena, Dalal Darshan, Butcher Barbara, Norgard Sanaz, Eldadah Zayd, Ellenbogen Kenneth A, Dickfeld Timm, Spragg David D, Marine Joseph E, Guallar Eliseo, Tomaselli Gordon F

СтатьяМногоцентровое исследованиеНаблюдательное исследованиеПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Primary prevention implantable cardioverter defibrillators (ICDs) reduce all-cause mortality, but the benefits are heterogeneous. Current risk stratification based on left ventricular ejection fraction has limited discrimination power. We hypothesize that biomarkers for inflammation, neurohumoral activation, and cardiac injury can predict appropriate shocks and all-cause mortality in patients with primary prevention ICDs.

METHODS AND

RESULTS

The Prospective Observational Study of Implantable Cardioverter Defibrillators (PROSe-ICD) enrolled 1189 patients with systolic heart failure who underwent ICD implantation for primary prevention of sudden cardiac death. The primary end point was an ICD shock for adjudicated ventricular tachyarrhythmia. The secondary end point was all-cause mortality. After a median follow-up of 4.0 years, 137 subjects experienced an appropriate ICD shock and 343 participants died (incidence rates of 3.2 and 5.8 per 100 person-years, respectively). In multivariable-adjusted models, higher interleukin-6 levels increased the risk of appropriate ICD shocks. In contrast, C-reactive protein, interleukin-6, tumor necrosis factor-α receptor II, pro-brain natriuretic peptide (pro-BNP), and cardiac troponin T showed significant linear trends for increased risk of all-cause mortality across quartiles. A score combining these 5 biomarkers identified patients who were much more likely to die than to receive an appropriate shock from the ICD.

CONCLUSIONS

An increase in serum biomarkers of inflammation, neurohumoral activation, and myocardial injury increased the risk for death but poorly predicted the likelihood of an ICD shock. These findings highlight the potential importance of serum-based biomarkers in identifying patients who are unlikely to benefit from primary prevention ICDs.

CLINICAL TRIAL REGISTRATION URL: clinicaltrials.gov; Unique Identifier: NCT00733590.

Для цитирования: Cheng Alan, Zhang Yiyi, Blasco-Colmenares Elena, Dalal Darshan, Butcher Barbara, Norgard Sanaz, Eldadah Zayd, Ellenbogen Kenneth A, Dickfeld Timm, Spragg David D, Marine Joseph E, Guallar Eliseo, Tomaselli Gordon F. Protein biomarkers identify patients unlikely to benefit from primary prevention implantable cardioverter defibrillators: findings from the Prospective Observational Study of Implantable Cardioverter Defibrillators (PROSE-ICD).. Circulation. Arrhythmia and electrophysiology. 2014. DOI: 10.1161/circep.113.001705.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.