BACKGROUND

Cardiac resynchronization therapy with defibrillator (CRT-D) reduces morbidity and mortality among selected patients with heart failure in clinical trials. The effectiveness of this therapy in clinical practice has not been well studied.

METHODS AND

RESULTS

We compared a cohort of 4471 patients from the National Cardiovascular Data Registry's Implantable Cardioverter-Defibrillator (ICD) Registry hospitalized primarily for heart failure and who received CRT-D between April 1, 2006, and December 31, 2009, to a historical control cohort of 4888 patients with heart failure without CRT-D from the Acute Decompensated Heart Failure National Registry (ADHERE) hospitalized between January 1, 2002, and March 31, 2006. Both registries were linked with Medicare claims to evaluate longitudinal outcomes. We included patients from the ICD Registry with left ventricular ejection fraction ≤35% and QRS duration ≥120 ms who were admitted for heart failure. We used Cox proportional hazards models to compare outcomes with and without CRT-D after adjustment for important covariates. After multivariable adjustment, CRT-D was associated with lower 3-year risks of death (hazard ratio, 0.52; 95% confidence interval, 0.48-0.56; P<0.001), all-cause readmission (hazard ratio, 0.69; 95% confidence interval, 0.65-0.73; P<0.001), and cardiovascular readmission (hazard ratio, 0.60; 95% confidence interval, 0.56-0.64; P<0.001). The association of CRT-D with mortality did not vary significantly among subgroups defined by age, sex, race, QRS duration, and optimal medical therapy.

CONCLUSIONS

CRT-D was associated with lower risks of mortality, all-cause readmission, and cardiovascular readmission than medical therapy alone among patients with heart failure in community practice.

Для цитирования: Khazanie Prateeti, Hammill Bradley G, Qualls Laura G, Fonarow Gregg C, Hammill Stephen C, Heidenreich Paul A, Al-Khatib Sana M, Piccini Jonathan P, Masoudi Frederick A, Peterson Pamela N, Curtis Jeptha P, Hernandez Adrian F, Curtis Lesley H. Clinical effectiveness of cardiac resynchronization therapy versus medical therapy alone among patients with heart failure: analysis of the ICD Registry and ADHERE.. Circulation. Heart failure. 2014. DOI: 10.1161/circheartfailure.113.000838.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.