MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jacc.2014.05.060

Медицинская библиотека · Journal of the American College of Cardiology · 2014

Clinical effectiveness of CRT and ICD therapy in heart failure patients by racial/ethnic classification: insights from the IMPROVE HF registry.

Ziaeian Boback, Zhang Yan, Albert Nancy M, Curtis Anne B, Gheorghiade Mihai, Heywood J Thomas, Mehra Mandeep R, O'Connor Christopher M, Reynolds Dwight, Walsh Mary Norine, Yancy Clyde W, Fonarow Gregg C

СтатьяМногоцентровое исследованиеНаблюдательное исследованиеПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Clinical trials have demonstrated benefit for cardiac resynchronization therapy (CRT) and implantable cardioverter-defibrillator (ICD) therapies in patients with heart failure with reduced ejection fraction (HFrEF); yet, questions have been raised with regard to the benefit of device therapy for minorities.

OBJECTIVES

The purpose of this study was to determine the clinical effectiveness of CRT and ICD therapies as a function of race/ethnicity in outpatients with HFrEF (ejection fraction ≤35%).

METHODS

Data from IMPROVE HF (Registry to Improve the Use of Evidence-Based Heart Failure Therapies in the Outpatient Setting) were analyzed by device status and race/ethnicity among guideline-eligible patients for mortality at 24 months. Multivariate Generalized Estimating Equations analyses were conducted, adjusting for patient and practice characteristics.

RESULTS

The ICD/cardiac resynchronization defibrillator (CRT-D)-eligible cohort (n = 7,748) included 3,391 (44%) non-Hispanic white, 719 (9%) non-Hispanic black, and 3,638 (47%) other racial/ethnic minorities or race-not-documented patients. The cardiac resynchronization pacemaker (CRT-P)/CRT-D-eligible cohort (n = 1,188) included 596 (50%) non-Hispanic white, 99 (8%) non-Hispanic black, and 493 (41%) other/not-documented patients. There was clinical benefit associated with ICD/CRT-D therapy (adjusted odds ratio: 0.64, 95% confidence interval: 0.52 to 0.79, p = 0.0002 for 24-month mortality), which was of similar proportion in white, black, and other minority/not-documented patients (device-race/ethnicity interaction p = 0.7861). For CRT-P/CRT-D therapy, there were also associated mortality benefits (adjusted odds ratio: 0.55, 95% confidence interval: 0.33 to 0.91, p = 0.0222), and the device-race/ethnicity interaction was not significant (p = 0.5413).

CONCLUSIONS

The use of guideline-directed CRT and ICD therapy was associated with reduced 24-month mortality without significant interaction by racial/ethnic group. Device therapies should be offered to eligible heart failure patients, without modification based on race/ethnicity.

Для цитирования: Ziaeian Boback, Zhang Yan, Albert Nancy M, Curtis Anne B, Gheorghiade Mihai, Heywood J Thomas, Mehra Mandeep R, O'Connor Christopher M, Reynolds Dwight, Walsh Mary Norine, Yancy Clyde W, Fonarow Gregg C. Clinical effectiveness of CRT and ICD therapy in heart failure patients by racial/ethnic classification: insights from the IMPROVE HF registry.. Journal of the American College of Cardiology. 2014. DOI: 10.1016/j.jacc.2014.05.060.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.