MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ijchv.2014.06.008

Медицинская библиотека · International journal of cardiology. Heart & vessels · 2014

Regional variations in baseline characteristics of cardiac rhythm device recipients: The PANORAMA observational cohort study.

Al Kandari Fawziah, Erglis Andrejs, Sweidan Raed, Dannheimer Ingrid, Sepsi Milan, Bénézet Juan, Padour Michal, Naik Ajay, Escudero Jaime, West Teena, Holbrook Reece, Lorgat Faizel, PANORAMA investigators

СтатьяПеревод в очереди

Аннотация

BACKGROUND

The PANORAMA study was designed to collect concurrent data on subjects from different worldwide regions implanted with CRM devices.

METHODS

In this prospective, multi-center study, we analyzed baseline data on 8586 subjects implanted with CRM devices with no additional selection criteria (66% pacemaker (IPG), 16% implantable cardiac defibrillators (ICD), 17% cardiac resynchronization therapy (CRT) and < 1% Internal Loop Recorder) from 156 hospitals across 6 geographical regions between 2005 and 2011.

RESULTS

Regardless of the device implanted, subjects from the Middle East and India often had more diabetes than other regions. Eastern and Western Europe had higher rates of atrial fibrillation reported, and men were more likely to smoke than women (46% vs 11%, p < 0.001). Within the CRT cohort there was significant variation in the proportion of males receiving a device, ranging from 55% in India to 83% in Eastern Europe.

CONCLUSIONS

We provide comprehensive descriptive data on patients receiving CRM devices from a range of geographies that are not typically reported in literature. We found significant variations in clinical characteristics and implant practices. Long term follow-up data will help evaluate if these variations require adjustments to outcome expectations.

Для цитирования: Al Kandari Fawziah, Erglis Andrejs, Sweidan Raed, Dannheimer Ingrid, Sepsi Milan, Bénézet Juan, Padour Michal, Naik Ajay, Escudero Jaime, West Teena, Holbrook Reece, Lorgat Faizel, PANORAMA investigators. Regional variations in baseline characteristics of cardiac rhythm device recipients: The PANORAMA observational cohort study.. International journal of cardiology. Heart & vessels. 2014. DOI: 10.1016/j.ijchv.2014.06.008.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.