MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/europace/eut384

Медицинская библиотека · Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2014

Health economic evaluation of single-lead atrial pacing vs. dual-chamber pacing in sick sinus syndrome.

Oddershede Lars, Riahi Sam, Nielsen Jens Cosedis, Hjortshøj Søren, Andersen Henning Rud, Ehlers Lars

СтатьяМногоцентровое исследованиеРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

AIMS: The recent Danish Multicentre Randomized Trial on Single-Lead Atrial (AAIR) Pacing versus Dual-Chamber (DDDR) Pacing in Sick Sinus Syndrome (DANPACE) suggested DDDR pacing as standard care. However, previous findings supported the routine use of AAIR pacing. This study investigated the cost-effectiveness of DDDR pacing compared with AAIR pacing for sick sinus syndrome.

METHODS AND

RESULTS

A decision-analytical model based on patient-level data from three randomized trials was designed from the Danish healthcare system's perspective. The main outcomes were lifetime costs, quality-adjusted lifeyears (QALYs), and net monetary benefit. Quality-adjusted lifeyears were calculated by utilizing community-based preferences. Costs were calculated by utilizing the extensive data on resource consumption, from the DANPACE trial. Data were pooled and adjusted for baseline differences. Dual-chamber pacing was shown to be cost-effective in all the analyses using a willingness-to-pay (WTP) threshold of £20,000/QALY, and most analyses using a WTP of £30,000/QALY. When pooling the data and adjusting for baseline differences, Monte Carlo simulations revealed a 51-71% probability of DDDR pacing being cost-effective at a WTP of £20,000/QALY, and a 42-58% probability at a WTP of £30,000/QALY. Dual-chamber pacing was most likely to be cost-effective among elderly patients with comorbidity. The expected value of perfect information was low and initiation of additional publicly funded Danish trials was discouraged.

CONCLUSION

Dual-chamber pacing is likely to be a cost-effective treatment for sick sinus syndrome patients.

Для цитирования: Oddershede Lars, Riahi Sam, Nielsen Jens Cosedis, Hjortshøj Søren, Andersen Henning Rud, Ehlers Lars. Health economic evaluation of single-lead atrial pacing vs. dual-chamber pacing in sick sinus syndrome.. Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology. 2014. DOI: 10.1093/europace/eut384.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.