MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/j.1540-8183.2011.00677.x

Медицинская библиотека · Journal of interventional cardiology · 2011

Long-term safety and effectiveness of drug-eluting stents compared to bare metal stents following successful PCI in non-ST-elevation myocardial infarction: findings from the Guthrie Health Off-Label StenT (GHOST) Registry.

Harjai Kishore J, Sattur Sudhakar, Orshaw Pamela, Boura Judy

СтатьяПеревод в очереди

Аннотация

BACKGROUND

The long-term safety and effectiveness of drug-eluting stents (DES) versus bare metal stents (BMS) in non-ST-segment elevation myocardial infarction (NSTEMI) beyond 2 years after percutaneous coronary intervention (PCI) is unknown.

METHODS

We studied 674 NSTEMI patients who underwent successful PCI with DES (n = 323) or BMS (n = 351). The primary study end-points were time to occurrence of death or nonfatal recurrent myocardial infarction (MI), and stent thrombosis (ST). Secondary end-points included time to occurrence of target vessel revascularization (TVR) and any major adverse cardiovascular event (MACE, defined as the composite of death, MI, ST, TVR).

RESULTS

The DES and BMS groups were well matched except that DES patients received dual antiplatelet therapy for a longer duration and had smaller final vessel diameter. In survival analysis, at a mean follow-up of 1333 ± 659 days after PCI, the DES group had similar incidence of death/myocardial infarction (24% vs. 27%, log rank p = 0.23) and ST (4.0% vs. 2.6%, p = 0.18) as the BMS group. The DES patients had lower incidence of TVR (8.1% vs. 17%, p = 0.0018) but similar MACE (26% vs. 37%, p = 0.31). In multivariable analysis, DES vs. BMS implantation showed no significant impact on death/myocardial infarction [adjusted hazards ratio (HR) 1.0, 95% confidence intervals (CI) 0.7-1.4], ST (HR 1.7; CI 0.7 - 4.0), or MACE (HR 0.8; CI 0.6 - 1.1). However, TVR was lower in the DES group (HR 0.4; CI 0.3 - 0.7).

CONCLUSION

In patients presenting with NSTEMI, DES implantation appears to be as safe as BMS implantation at long-term follow-up. In addition, DES are effective in reducing TVR compared to BMS.

Для цитирования: Harjai Kishore J, Sattur Sudhakar, Orshaw Pamela, Boura Judy. Long-term safety and effectiveness of drug-eluting stents compared to bare metal stents following successful PCI in non-ST-elevation myocardial infarction: findings from the Guthrie Health Off-Label StenT (GHOST) Registry.. Journal of interventional cardiology. 2011. DOI: 10.1111/j.1540-8183.2011.00677.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.