BACKGROUND

There is few information on the long-term efficacy and safety of sirolimus-eluting stents (SES) and paclitaxel-eluting stents (PES) compared to bare metal stents (BMS) in all-comer percutaneous coronary intervention (PCI)-patients complicated by renal insufficiency (RI).

OBJECTIVE

Our aim was to assess the 6-year clinical outcome of PCI-patients with RI treated exclusively with BMS, SES, or PES in our academic hospital.

METHODS

A total of 1382 patients, included in three cohorts of consecutive PCI-patients (BMS = 392; SES = 498; PES = 492), were categorized by creatinine clearance calculated by the Cockroft-Gault formula (normal kidney function ≥ 90; mild RI = 60-89; moderate RI < 60) and systematically followed for the occurrence of major adverse cardiac events (MACE).

RESULTS

Mortality rates were significantly higher for patients with moderate RI compared to mild RI and normal kidney function at 6 years (Kaplan-Meier estimate: moderate RI (34%) vs. mild RI (12%), P < 0.001; moderate RI (34%) vs. normal kidney function (8%), P < 0.001). After multivariate Cox-regression analysis, SES and PES decreased the occurrence of target-vessel revascularization (TVR) and MACE at 6 years in patients with a normal creatinine clearance compared to BMS [adjusted hazard ratio (aHR) = 0.48, 95% CI: 0.28-0.84; aHR = 0.75, 95% CI: 0.57-0.97, respectively] with no significant effect on mortality. Safety- and efficacy end points were comparable for the three stent types in patients with mild- and moderate renal function.

CONCLUSION

Patients with a normal creatinine clearance had significant improvement in TVR and MACE rates after SES- or PES implantation compared to BMS at 6 years. However, there was no superiority of both drug-eluting stents over BMS in safety and efficacy end points for patients with impaired renal function.

Для цитирования: Simsek Cihan, Magro Michael, Boersma Eric, Onuma Yoshinobu, Nauta Sjoerd, Valstar Gideon, van Geuns Robert-Jan, van der Giessen Willem, van Domburg Ron, Serruys Patrick, Interventional Cardiologists of Thoraxcenter. Impact of renal insufficiency on safety and efficacy of drug-eluting stents compared to bare-metal stents at 6 years.. Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions. 2012. DOI: 10.1002/ccd.23199.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.