Медицинская библиотека · Journal of cardiothoracic and vascular anesthesia · 2011

Predictive value of the additive and logistic EuroSCOREs in patients undergoing aortic valve replacement.

Koene Bart M J A, van Straten Albert H M, Soliman Hamad Mohamed A, Berreklouw Eric, Ter Woorst Joost F, Tan M Erwin, van Zundert André J

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

The purpose of this study was to evaluate the accuracy of the additive and logistic EuroSCOREs in predicting the operative mortality in patients undergoing aortic valve replacement (AVR) with or without coronary artery bypass graft (CABG) surgery.

DESIGN

This was a retrospective analysis of prospectively collected data.

SETTING

This was a single-center study performed in an educational hospital.

PARTICIPANTS

All patients (n = 1,885) who underwent AVR with (n = 813) or without (n = 1,072) CABG surgery between 1998 and 2007.

INTERVENTIONS: AVR with or without CABG surgery.

MEASUREMENTS AND MAIN

RESULTS

Variable life-adjusted display curves were constructed to compare the observed operative mortality with the additive and logistic EuroSCOREs. The receiver operating characteristics (ROC) curve was used to determine the discriminatory power of the additive and logistic EuroSCOREs. Calibration between the predicted and the observed operative mortality was checked by comparing the predicted probability of the mortality with the additive and logistic EuroSCORE. In the isolated AVR group, the additive EuroSCORE was 5.8% predicted mortality and the logistic EuroSCORE was 7.2%, whereas the observed operative mortality was 3.2%. In the AVR with CABG surgery group, the additive EuroSCORE was 7.2% and the logistic EuroSCORE was 8.8%, whereas the observed operative mortality was 5.3%. ROC curve analyses showed a high discriminatory power for both EuroSCOREs in both patient groups.

CONCLUSIONS

Although the additive and the logistic EuroSCOREs had good discriminatory power, they were not able to predict the actual operative mortality accurately. Both EuroSCOREs overestimated the operative mortality, especially in low-risk patients.

Для цитирования: Koene Bart M J A, van Straten Albert H M, Soliman Hamad Mohamed A, Berreklouw Eric, Ter Woorst Joost F, Tan M Erwin, van Zundert André J. Predictive value of the additive and logistic EuroSCOREs in patients undergoing aortic valve replacement.. Journal of cardiothoracic and vascular anesthesia. 2011. DOI: 10.1053/j.jvca.2011.05.010.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.