m+Medelevator.RU
← Поиск публикаций
Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2010

Pre-implantation implantable cardioverter defibrillator concerns and Type D personality increase the risk of mortality in patients with an implantable cardioverter defibrillator.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Pedersen Susanne S, van den Broek Krista C, Erdman Ruud A M, Jordaens Luc, Theuns Dominic A M J

Аннотация

AIMS: Little is known about the influence of psychological factors on prognosis in implantable cardioverter defibrillator (ICD) patients. We examined the influence of the distressed personality (Type D) and pre-implantation device concerns on short-term mortality in ICD patients.

METHODS AND RESULTS: Consecutively implanted ICD patients (N = 371; 79.5% men) completed the Type D Scale and the ICD Patient Concerns questionnaire prior to implantation and were followed up for short-term mortality. The prevalence of Type D was 22.4%, whereas 34.2% had high levels of ICD concerns. The incidence of mortality was higher in Type D vs. non-Type D patients [13.3% vs. 4.92%; hazard ratio (HR): 2.74; 95% confidence interval (CI): 1.24-6.03] and in patients with high vs. low levels of ICD concerns (11.0% vs. 4.5%; HR: 2.38; 95% CI: 1.08-5.23). Type D personality (HR: 2.79; 95% CI: 1.25-6.21) and high levels of ICD concerns (HR: 2.38; 95% CI: 1.06-5.34) remained independent predictors of mortality in separate analyses, adjusting for sex, age, ICD indication, coronary artery disease, and shocks. Patients with clustering of both Type D personality and high levels of pre-implantation concerns (HR: 3.86; 95% CI: 1.64-9.10) had a poorer survival compared with patients with one or none of these risk markers in adjusted analysis. Shocks during the follow-up period were also associated with mortality (HR: 3.09; 95% CI: 1.36-7.04).

CONCLUSION: Patients with a distressed personality and high levels of pre-implantation device-related concerns had a poorer prognosis, independent of other risk markers including shocks. This subgroup of patients should be identified in clinical practice and would likely benefit from a combined distress management programme and cardiac rehabilitation.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты