DOI 10.1093/europace/eup068

Медицинская библиотека · Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2009

Lifetime cost-effectiveness of prophylactic implantation of a cardioverter defibrillator in patients with reduced left ventricular systolic function: results of Markov modelling in a European population.

Cowie Martin R, Marshall Deborah, Drummond Michael, Ferko Nicole, Maschio Michael, Ekman Matthias, de Roy Luc, Heidbuchel Hein, Verboven Yves, Braunschweig Frieder, Linde Cecilia, Boriani Giuseppe

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

AIMS: Current European guidelines recommend prophylactic implantation of cardioverter defibrillators (ICDs) in patients with a reduced left ventricular ejection fraction (LVEF) who are not in NYHA class IV and have reasonable life expectancy. Cost and benefit implications of this recommendation have not been reported from a European perspective.

METHODS AND

RESULTS

Markov modelling estimated lifetime costs and effects [life years (LY) and quality-adjusted LY (QALY) gained] of prophylactic ICD implantation vs. conventional treatment, among patients with a reduced LVEF. Efficacy was estimated from a meta-analysis of mortality rates in the six primary prevention trials with inclusion criteria matching ACC/AHA/ESC Class I or IIa recommendations. Direct medical costs were estimated using Belgian national references. Costs and effects were discounted at 3 and 1.5% per annum, respectively. Probabilistic sensitivity and scenario analyses estimated the uncertainty around the incremental cost-effectiveness ratio. An ICD implantation increased the lifetime direct costs by euro 46,413. Estimated mean LY/QALY gained were 1.88/1.57, respectively. Probabilistic analysis estimated mean lifetime cost per QALY gained as euro 31,717 (95% CI: euro 19,760-euro 61,316). Cost-effectiveness was influenced most by ICD efficacy, time to replacement, utility, and patient age at implantation.

CONCLUSION

In a European healthcare setting, prophylactic ICD implantation may be cost-effective if current guidelines for patients with a reduced LVEF are followed.

Для цитирования: Cowie Martin R, Marshall Deborah, Drummond Michael, Ferko Nicole, Maschio Michael, Ekman Matthias, de Roy Luc, Heidbuchel Hein, Verboven Yves, Braunschweig Frieder, Linde Cecilia, Boriani Giuseppe. Lifetime cost-effectiveness of prophylactic implantation of a cardioverter defibrillator in patients with reduced left ventricular systolic function: results of Markov modelling in a European population.. Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology. 2009. DOI: 10.1093/europace/eup068.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.