Hospital variation and characteristics of implantable cardioverter-defibrillator use in patients with heart failure: data from the GWTG-HF (Get With The Guidelines-Heart Failure) registry.

Shah Bimal, Hernandez Adrian F, Liang Li, Al-Khatib Sana M, Yancy Clyde W, Fonarow Gregg C, Peterson Eric D, Get With The Guidelines Steering Committee

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVES

The aim of this study was to describe hospital variation and factors associated with adherence to guidelines for implantable cardioverter-defibrillator (ICD) therapy.

BACKGROUND

Studies have shown incomplete application of ICD therapy in eligible heart failure (HF) patients.

METHODS

New or discharge prescription rates for ICD therapy (ejection fraction <or=30% without documented ICD contraindications) for hospitals were calculated from participants in the GWTG-HF (Get With The Guidelines-Heart Failure) registry during January 2005 to June 2007. With hierarchical modeling, hospitals' patient case-mix adjusted ICD rate and hospital factors associated with ICD use were determined. The association of ICD rate and other quality of care indicators and procedure use was determined.

RESULTS

Overall use of ICD in-hospital or planned implantation rate was 20%. This rate ranged widely among hospitals, from 1% among the lowest tertile to 35% among the top tertile (p < 0.01). After adjusting for patient case mix, independent hospital characteristics associated with higher ICD use were percutaneous coronary intervention, coronary artery bypass grafting, and heart transplant capability as well as larger hospital bed size (p < 0.01). Hospital Centers for Medicare and Medicaid Services/Joint Commission on the Accreditation of Healthcare Organizations performance measures (discharge instructions, angiotensin-converting enzyme inhibitor/angiotensin II receptor blocker use, smoking cessation; p >or= 0.05) were similar across ICD, whereas higher ICD-rate hospitals had higher adherence to GWTG-HF performance measures (beta-blocker use, evidence-based beta-blocker use, aldosterone-antagonist, hydralazine/nitrate; p < 0.05) except warfarin in patients with atrial fibrillation (p = 0.18).

CONCLUSIONS

There is significant unexplained hospital variation in the use of ICD therapy among potentially eligible HF patients. However, hospitals that use ICD therapy more often also have more rapidly adopted other newer evidence-based HF therapies.

Для цитирования: Shah Bimal, Hernandez Adrian F, Liang Li, Al-Khatib Sana M, Yancy Clyde W, Fonarow Gregg C, Peterson Eric D, Get With The Guidelines Steering Committee. Hospital variation and characteristics of implantable cardioverter-defibrillator use in patients with heart failure: data from the GWTG-HF (Get With The Guidelines-Heart Failure) registry.. Journal of the American College of Cardiology. 2009. DOI: 10.1016/j.jacc.2008.09.045.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.