MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jacc.2005.01.008

Медицинская библиотека · Journal of the American College of Cardiology · 2005

The unrestricted use of paclitaxel- versus sirolimus-eluting stents for coronary artery disease in an unselected population: one-year results of the Taxus-Stent Evaluated at Rotterdam Cardiology Hospital (T-SEARCH) registry.

Ong Andrew T L, Serruys Patrick W, Aoki Jiro, Hoye Angela, van Mieghem Carlos A G, Rodriguez-Granillo Gaston A, Valgimigli Marco, Sonnenschein Karel, Regar Evelyn, van der Ent Martin, de Jaegere Peter P T, McFadden Eugene P, Sianos Georgios, van der Giessen Willem J, de Feyter Pim J, van Domburg Ron T

Оценочное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVES

We investigated the efficacy of paclitaxel-eluting stents (PES) compared to sirolimus-eluting stents (SES) when used without restriction in unselected patients.

BACKGROUND

Both SES and PES have been separately shown to be efficacious when compared to bare stents. In unselected patients, no direct comparison between the two devices has been performed.

METHODS

Paclitaxel-eluting stents have been used as the stent of choice for all percutaneous coronary interventions in the prospective Taxus-Stent Evaluated At Rotterdam Cardiology Hospital (T-SEARCH) registry. A total of 576 consecutive patients with de novo coronary artery disease exclusively treated with PES were compared with 508 patients treated with SES from the Rapamycin-Eluting Stent Evaluated At Rotterdam Cardiology Hospital (RESEARCH) registry.

RESULTS

The PES patients were more frequently male, more frequently treated for acute myocardial infarction, had longer total stent lengths, and more frequently received glycoprotein IIb/IIIa inhibitors. At one year, the raw cumulative incidence of major adverse cardiac events was 13.9% in the PES group and 10.5% in the SES group (unadjusted hazard ratio [HR] 1.33, 95% confidence interval [CI] 0.95 to 1.88, p = 0.1). Correction for differences in the two groups resulted in an adjusted HR of 1.16 (95% CI 0.81 to 1.64, p = 0.4, using significant univariate variables) and an adjusted HR of 1.20 (95% CI 0.85 to 1.70, p = 0.3, using independent predictors). The one-year cumulative incidence of clinically driven target vessel revascularization was 5.4% versus 3.7%, respectively (HR 1.38, 95% CI 0.79 to 2.43, p = 0.3).

CONCLUSIONS

The universal use of PES in an unrestricted setting is safe and is associated with a similar adjusted outcome compared to SES. The inferior trend in crude outcome seen in PES was due to its higher-risk population. A larger, randomized study enrolling an unselected population may assist in determining the relative superiority of either device.

Для цитирования: Ong Andrew T L, Serruys Patrick W, Aoki Jiro, Hoye Angela, van Mieghem Carlos A G, Rodriguez-Granillo Gaston A, Valgimigli Marco, Sonnenschein Karel, Regar Evelyn, van der Ent Martin, de Jaegere Peter P T, McFadden Eugene P, Sianos Georgios, van der Giessen Willem J, de Feyter Pim J, van Domburg Ron T. The unrestricted use of paclitaxel- versus sirolimus-eluting stents for coronary artery disease in an unselected population: one-year results of the Taxus-Stent Evaluated at Rotterdam Cardiology Hospital (T-SEARCH) registry.. Journal of the American College of Cardiology. 2005. DOI: 10.1016/j.jacc.2005.01.008.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.