Sá Juliana Marques, Lopes Sara de Campos, Santos Maria Joana, Alves Marta, Lages Adriana De Sousa
Аннотация
OBJECTIVE: To evaluate glycemic control according to the number of daily basal rates (BRs) in type 1 diabetes patients using continuous subcutaneous insulin infusion (CSII).
SUBJECTS AND METHODS: Cross-sectional study of patients treated with an open-loop CSII for at least 6 months and using a flash glucose monitoring system. Patients were divided into 2 groups: group 1 (G1) and group 2 (G2), with ≤4 and >4 BRs/24h, respectively. The groups were compared regarding HbA1c, time in range (TIR), time above range (TAR), time below range (TBR), glucose management indicator (GMI), glucose variability and data related to hypoglycemia. Regression models were performed.
RESULTS: The study included 99 patients (n = 55 in G1; n = 44 in G2). Median (Interquartile range) overall age was 30 (17) years, with 19.5 (48) and 51 (77) months of CSII use, respectively. The median number of different BRs was 3 (2) for G1 and 6 (2) for G2. There were no differences concerning age, sex, educational stage, weight, and insulin analog used. G2 had longer disease duration, longer CSII use, and higher total basal daily dose/kg. No significant differences regarding HbA1c, median glucose, GMI, TIR, TAR, and CV were found. G2 patients had more hypoglycemia, more asymptomatic hypoglycemia, and higher TBR. After adjusting for potential confounders, G1 maintained a lower risk of asymptomatic hypoglycemia.
CONCLUSION: Programming open-loop CSII devices with more than 4 BRs does not improve metabolic control. Additionally, it seems to be a risk factor for hypoglycemia and was an independent predictor for asymptomatic hypoglycemia.
SUBJECTS AND METHODS: Cross-sectional study of patients treated with an open-loop CSII for at least 6 months and using a flash glucose monitoring system. Patients were divided into 2 groups: group 1 (G1) and group 2 (G2), with ≤4 and >4 BRs/24h, respectively. The groups were compared regarding HbA1c, time in range (TIR), time above range (TAR), time below range (TBR), glucose management indicator (GMI), glucose variability and data related to hypoglycemia. Regression models were performed.
RESULTS: The study included 99 patients (n = 55 in G1; n = 44 in G2). Median (Interquartile range) overall age was 30 (17) years, with 19.5 (48) and 51 (77) months of CSII use, respectively. The median number of different BRs was 3 (2) for G1 and 6 (2) for G2. There were no differences concerning age, sex, educational stage, weight, and insulin analog used. G2 had longer disease duration, longer CSII use, and higher total basal daily dose/kg. No significant differences regarding HbA1c, median glucose, GMI, TIR, TAR, and CV were found. G2 patients had more hypoglycemia, more asymptomatic hypoglycemia, and higher TBR. After adjusting for potential confounders, G1 maintained a lower risk of asymptomatic hypoglycemia.
CONCLUSION: Programming open-loop CSII devices with more than 4 BRs does not improve metabolic control. Additionally, it seems to be a risk factor for hypoglycemia and was an independent predictor for asymptomatic hypoglycemia.