Accuracy of documented administration times for intravenous antimicrobial drugs and impact on dosing decisions.
Аннотация
AIMS: Accurate documentation of medication administration time is imperative for many therapeutic decisions, including dosing of intravenous antimicrobials. The objectives were to determine (1) the discrepancy between actual and documented administration times for antimicrobial infusions and (2) whether day of the week, time of day, nurse-to-patient ratio and drug impacted accuracy of documented administration times.
METHODS
Patient and dosing data were collected (June-August 2019) for 55 in-patients receiving antimicrobial infusions. "Documented" and "actual" administration times (n = 660) extracted from electronic medication management systems and smart infusion pumps, respectively, were compared. Influence of the day (weekday/weekend), time of day (day/evening/night), nurse-to-patient ratio (high 1:1/low 1:5) and drug were examined. Monte Carlo simulation was used to predict the impact on dose adjustments for vancomycin using the observed administration time discrepancies compared to the actual administration time.
RESULTS
The median discrepancy between actual and documented administration times was 16 min (range, 2-293 min), with discrepancies greater than 60 minutes in 7.7% of administrations. Overall, discrepancies (median [range]) were similar on weekends (17 [2-293] min) and weekdays (16 [2-188] min), and for high (16 [2-157] min) and low nurse-to-patient ratio wards (16 [2-293] min). Discrepancies were smallest for night administrations (P < .05), and antimicrobials with shorter half-lives (P < .0001). The observed discrepancies in vancomycin administration time resulted in a different dose recommendation in 58% of cases (30% higher, 28% lower).
CONCLUSIONS
Overall, there were discrepancies between actual and documented antimicrobial infusion administration times. For vancomycin, these discrepancies in administration time were predicted to result in inappropriate dose recommendations.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.