Analytical chemistry · 2026
Fluidly Confined CRISPR-Magnetic Microbots Empowered Homogeneous Electrochemical Biosensor for Amplified Detection and Discrimination of Cancer-Derived Extracellular Vesicle Subtypes.
СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Yang Limin, Tan Huilin, Wang Yujue, Zhang Jingang, Meng Xiangyu, Liu Xiaojuan, Hou Ting, Chen Weiqi, Li Feng
Аннотация
Accurate identification and profiling of multiple protein biomarkers on tumor-derived extracellular vesicles (tEVs) are crucial for noninvasive cancer subtyping diagnosis but remain technically challenging due to their high heterogeneity, low abundance in biofluids, and preisolation/purification processes. Herein, we developed a homogeneous electrochemical biosensor empowered by fluidly confined CRISPR-magnetic microbots for the amplified detection and sensitive discrimination of tEV subtypes. The CRISPR-magnetic microbots were constructed by engineering CRISPR/Cas12a and DNA icosahedra/doxorubicin (DNA-ICOS/DOX) on intracellularly gelated magnetic cells (IGMCs). Benefiting from the synergistic effects of spatial confinement and membrane fluidity to elevate the local concentration and collision efficiency, the activity of CRISPR/Cas12a was found to be greatly enhanced on IGMCs. For selective sorting of tEVs, a logic-gated aptamer system was used to orthogonally label tEV subpopulations, which further triggers the trans-cleavage activity of CRISPR/Cas12a, resulting in the release of massive DNA-ICOS/DOX into solution. After magnetic separation, the liberated DOX molecules generate a strong electrochemical signal. Particularly, the CRISPR-magnetic microbots could efficiently reduce the background signal, endowing a significantly improved signal-to-noise ratio. Therefore, by combining the CRISPR-magnetic microbots with the dual-target-guided orthogonal barcoding strategy in a homogeneous electrochemical biosensor, precise identification and sensitive detection of tEVs were successfully achieved. More significantly, this assay achieves accurate cancer subtyping in clinical samples, demonstrating its potential as a robust, noninvasive tool for high-accuracy disease screening, classification, and progression monitoring.