Evaluating an insulin infusion protocol in an acute care setting.

Сравнительное исследованиеОценочное исследованиеСтатьяПоддержка правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Locke Christy, McEuen Judy, Felder Robert S, Lesselroth Blake, Barrett Thomas W, Stevens Brent, Pope Diana S

Аннотация

OBJECTIVE: The objective of the present study was to evaluate the adherence, safety, and effectiveness of a paper versus an electronic insulin infusion protocol.

DESIGN: This quasi-experimental implementation study compared experimental and control groups using a nonrandomized prospective cohort design.

SETTING: The study was performed at 2 surgical units within a federal tertiary care teaching hospital.

SAMPLE: Fifty-eight registered nurses volunteered.

METHODS: We compared time intervals using electronic time stamps from glucometers and insulin infusion devices to measure protocol adherence. We assessed perceived adherence using a nurse survey, and, to evaluate safety, we reviewed each paper protocol infusion calculation for correctness.

FINDINGS: Median times from blood glucose acquisition to infusion rate adjustment did not differ significantly between groups (P = .215). The majority of infusions (96.6%) had glucose acquisition times within the acceptable range. Median values of time to next "glucose due" did not differ significantly (P = .88), and relative variation in median glucose reporting times did not differ significantly between groups (P = .16). Evaluation of 877 paper protocol entries demonstrated a 10.7% (n = 94) calculation error rate. Registered nurses within the electronic group reported greater ease in balancing workload when compared with paper protocol use (P = .03). Attitudes did not differ significantly between groups in areas of determining infusion adjustment, bolus insulin dose, next glucose due, ease of access, understanding protocol, or overall satisfaction.

CONCLUSIONS: This study demonstrates that one can adhere to an insulin infusion protocol, regardless of the format (paper or electronic), in the medical-surgical setting. Our results suggest there are safety and nurse workload benefits when an electronic protocol was used.

IMPLICATIONS: Adherence, safety, and effectiveness can be achieved when using insulin infusion in the medical-surgical setting.