Feasibility and Safety of the Direct Occluded Vessel Puncture Technique as a New Access Site for Complex Peripheral Artery Occlusive Disease.
Аннотация
AIM: This study aims to describe the feasibility and safety of direct occluded vessel puncture as a new access site for complex peripheral artery occlusive disease.
METHODS
Eleven consecutive patients with symptomatic peripheral artery disease underwent endovascular therapy using the direct occluded vessel puncture technique. The occluded vessel was punctured using a dedicated 20 G needle and the Hi-Torque Command 18 ST guidewire under duplex echo or fluoroscopic guidance, and a 6 Fr sheath was then inserted. Hemostasis was achieved with the Exoseal® Vascular Closure Device.
RESULTS
Direct occluded vessel puncture was achieved in 10 of 11 cases (90.9%), and procedural success was achieved in all cases. There were no in-hospital deaths or any complications, including bleeding, pseudoaneurysms, thrombosis, or surgical conversion.
CONCLUSION
The direct occluded vessel puncture technique using a 20 G needle and the Hi-Torque Command 18 ST is feasible and safe. This technique may also be used as an alternative option when there are no appropriate approach sites.