MedElevator Войти в исследования
← Поиск публикаций

DOI 10.4244/eij-d-20-00429

Медицинская библиотека · EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology · 2021

Clinical outcomes with unselected use of an ultrathin-strut sirolimus-eluting stent: a report from the Swedish Coronary Angiography and Angioplasty Registry (SCAAR).

Buccheri Sergio, Sarno Giovanna, Erlinge David, Renlund Henrik, Lagerqvist Bo, Grimfjärd Per, Witt Nils, Yndigegn Troels, Fröbert Ole, Persson Jonas, Böhm Felix, James Stefan K

СтатьяПеревод в очереди

Аннотация

AIMS: The aim of this study was to assess the real-world clinical performance of a sirolimus-eluting ultrathin-strut drug-eluting stent (DES) (Orsiro) in a large nationwide cohort of patients undergoing percutaneous coronary intervention (PCI).

METHODS AND

RESULTS

From the Swedish Coronary Angiography and Angioplasty Registry, the two-year outcomes of 4,561 patients implanted with Orsiro (Orsiro group) and 69,570 receiving other newer-generation DES (n-DES group) were analysed. The rate of definite stent thrombosis was low in both groups (0.67% and 0.83% for Orsiro and n-DES, respectively; adjusted hazard ratio [HR] 0.90, 95% confidence interval [CI]: 0.55-1.46, p-value 0.66). Restenosis was also infrequent (1.5% vs 2.0% with Orsiro and n-DES, adjusted HR 0.81, 95% CI: 0.63-1.03, p-value=0.09). The risk of target lesion revascularisation by PCI was lower in the Orsiro group (1.6% vs 2.3%, adjusted HR 0.75, 95% CI: 0.60-0.94, p-value=0.013). All-cause mortality and myocardial infarction did not show a statistically significant difference between the two groups (mortality of 7.5% in both groups, adjusted HR 0.99, 95% CI: 0.72-1.35, p-value=0.94; 6.0% vs 5.2% for myocardial infarction, adjusted HR 1.19, 95% CI: 1.00-1.43, p-value=0.06).

CONCLUSIONS

In a nationwide scenario, the use of a sirolimus-eluting ultrathin-strut DES portended favourable clinical outcomes.

Для цитирования: Buccheri Sergio, Sarno Giovanna, Erlinge David, Renlund Henrik, Lagerqvist Bo, Grimfjärd Per, Witt Nils, Yndigegn Troels, Fröbert Ole, Persson Jonas, Böhm Felix, James Stefan K. Clinical outcomes with unselected use of an ultrathin-strut sirolimus-eluting stent: a report from the Swedish Coronary Angiography and Angioplasty Registry (SCAAR).. EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology. 2021. DOI: 10.4244/eij-d-20-00429.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.