MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1159/000489316

Медицинская библиотека · Urologia internationalis · 2018

Adjustable Transobturator Male System after Failed Surgical Devices for Male Stress Urinary Incontinence: A Feasibility Study.

Angulo Javier C, Esquinas Cristina, Arance Ignacio, Rodríguez Andrés, Pereira Javier, Rabassa Miguel, Teyrouz Antoine, Teba Fernando, Celada Guillermo, Marcelino João P, Martins Francisco E, Manso Margarida, Cruz Francisco

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

Feasibility study to evaluate the efficacy and safety of Adjustable Transobturator Male System (ATOMS) after failed surgical devices for male stress urinary incontinence (SUI).

MATERIALS AND

METHODS

Thirty patients were implanted with ATOMS after they were implanted with surgical device/s previously. SUI severity was evaluated as dryness (0-1 pad/day), mild (2 pads/day), moderate (3-5 pads/day), or severe (≥6 pads/day). Change in pad-test and pad-count after adjustment, operative parameters, patient satisfaction, and number and grade of complications were investigated.

RESULTS

Previous failed treatment methods were artificial urinary sphincter (AUS; n = 19), Advance (n = 10), and Virtue (n = 1). Six cases had multiple previous treatments. Preoperative SUI was mild 6 (20%), moderate 11 (36.7%), and severe 13 (43.3%). Median pad-test decreased from 435 mL baseline to 10 mL after adjustment and pad-count from 4 to 0. Dry-rate was 76.7 and 83.3% declared satisfied. Postoperative SUI distribution was mild in 3 (10%) and moderate in 4 (13.3%). No patient had urinary retention after catheter removal. Complications presented in 4 (13.3%; 3 grade-I, 1 grade-II). After a median of 24 months follow-up, no system experienced infection or urethral erosion and 1 (3.3%) was removed for inefficacy.

CONCLUSION

Based on short-term efficacy and patient satisfaction, ATOMS can be a realistic alternative for male SUI after other failed systems, including AUS. The absence of urethral erosion and limited infective problems makes this alternative attractive for cases with previous failed treatments.

Для цитирования: Angulo Javier C, Esquinas Cristina, Arance Ignacio, Rodríguez Andrés, Pereira Javier, Rabassa Miguel, Teyrouz Antoine, Teba Fernando, Celada Guillermo, Marcelino João P, Martins Francisco E, Manso Margarida, Cruz Francisco. Adjustable Transobturator Male System after Failed Surgical Devices for Male Stress Urinary Incontinence: A Feasibility Study.. Urologia internationalis. 2018. DOI: 10.1159/000489316.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.