m+Medelevator.RU
← Поиск публикаций
EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology · 2018

Bioabsorbable polymer everolimus-eluting stents in patients with acute myocardial infarction: a report from the Swedish Coronary Angiography and Angioplasty Registry.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Buccheri Sergio, Sarno Giovanna, Lagerqvist Bo, Olivecrona Göran, Hambraeus Kristina, Witt Nils, Lindholm Daniel, Erlinge David, Angerås Oskar, James Stefan

Аннотация

AIMS: The clinical performance of the SYNERGY drug-eluting stent (DES) in patients with acute myocardial infarction (MI) has not been investigated in detail. We sought to report on the outcomes after SYNERGY DES (Boston Scientific, Marlborough, MA, USA) implantation in patients with MI undergoing percutaneous revascularisation (PCI).

METHODS AND RESULTS: We included all consecutive patients with MI undergoing PCI with the SYNERGY DES and newer-generation DES (n-DES group) in Sweden. From March 2013 to September 2016, a total of 36,292 patients, of whom 39.7% presented with ST-elevation MI, were included. As compared to patients in the n-DES group (n=31,403), patients in the SYNERGY group (n=4,889) were older and presented more often with left main or three-vessel disease involvement, as well as with restenotic lesions (p<0.001 for all parameters). The Kaplan-Meier estimates of ST at two years in the SYNERGY and n-DES groups were 0.69% and 0.81%, respectively (adjusted HR 1.00, 95% CI: 0.69-1.46; p=0.99). Clinically relevant restenosis was encountered in 1.48% and 1.25% of patients in the SYNERGY and n-DES groups, respectively (adjusted HR 1.05, 95% CI: 0.81-1.37; p=0.72). No differences in the risk of all-cause death and recurrent MI were found between the two groups after adjustment (adjusted HR 1.12, 95% CI: 0.98-1.28; p=0.10, and adjusted HR 0.95, 95% CI: 0.82-1.10; p=0.49, respectively).

CONCLUSIONS: In a large and unselected cohort of patients with MI undergoing percutaneous revascularisation with the SYNERGY DES, stent performance and clinical outcomes did not differ compared with other n-DES up to two years.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты