Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2017
Real-life clinical outcomes with everolimus eluting platinum chromium stent with an abluminal biodegradable polymer in patients from the Swedish Coronary Angiography and Angioplasty Registry (SCAAR).
СтатьяМногоцентровое исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Sarno Giovanna, Lagerqvist Bo, Olivecrona Göran, Varenhorst Christoph, Danielewicz Mikael, Hambraeus Kristina, Lindholm Daniel, Råmunddal Truls, Witt Nils, James Stefan
Аннотация
BACKGROUND: No previous studies have evaluated the performance of the Synergy stent in a large real-life population.
OBJECTIVES: To describe the initial real-life experience with a novel everolimus eluting platinum chromium stent with abluminal biodegradable polymer (SYNERGY) in unselected patients from a nationwide registry.
METHODS: All implanted Synergy stents were compared with other new generation drug eluting stents (n-DES) with >1,000 implantations in Sweden between March 2013 and October 2015. Restenosis, definite stent thrombosis (ST), myocardial infarction (MI) and death rates were assessed using propensity score and Cox regression analyses.
RESULTS: A total of 7,886 of Synergy stents and 64,429 other n-DES (BioMatrix, N = 1,953; Orsiro, N = 4,946; Promus Element Plus, N= 2,543; Promus Premier, N= 20,414; Xience Xpedition, N= 7,971, Resolute/Resolute Integrity, N = 19,021; Ultimaster, N = 1,156; Resolute Onyx, N = 6,425) were implanted in 42,357 procedures. Restenosis and stent thrombosis occurred in 642 and 314 cases, respectively, in the overall population at 1 year. The cumulative rate of restenosis (1.1% vs. 1.0%, adjusted HR: 1.24 95% CI: 0.88-1.75; P = 0.21) and ST (0.4% vs. 0.5%, adjusted HR: 0.97; 95% CI: 0.63-1.50; P = 0.17) up to 1 year was low in both the Synergy group and the other n-DES group. Death occurred in 5.2% versus 4.5% (adjusted HR: 1.14; 95% CI: 0.96-1.36; P = 0.11) and MI in 3.2% versus 3.5%, (adjusted HR: 1.11; 95% CI: 0.93-1.33; P = 0.24) up to 1 year.
CONCLUSIONS: In a large real-life population the Synergy stent appears to be safe and effective with a low rate of restenosis and ST comparable with other n-DES. © 2017 Wiley Periodicals, Inc.
OBJECTIVES: To describe the initial real-life experience with a novel everolimus eluting platinum chromium stent with abluminal biodegradable polymer (SYNERGY) in unselected patients from a nationwide registry.
METHODS: All implanted Synergy stents were compared with other new generation drug eluting stents (n-DES) with >1,000 implantations in Sweden between March 2013 and October 2015. Restenosis, definite stent thrombosis (ST), myocardial infarction (MI) and death rates were assessed using propensity score and Cox regression analyses.
RESULTS: A total of 7,886 of Synergy stents and 64,429 other n-DES (BioMatrix, N = 1,953; Orsiro, N = 4,946; Promus Element Plus, N= 2,543; Promus Premier, N= 20,414; Xience Xpedition, N= 7,971, Resolute/Resolute Integrity, N = 19,021; Ultimaster, N = 1,156; Resolute Onyx, N = 6,425) were implanted in 42,357 procedures. Restenosis and stent thrombosis occurred in 642 and 314 cases, respectively, in the overall population at 1 year. The cumulative rate of restenosis (1.1% vs. 1.0%, adjusted HR: 1.24 95% CI: 0.88-1.75; P = 0.21) and ST (0.4% vs. 0.5%, adjusted HR: 0.97; 95% CI: 0.63-1.50; P = 0.17) up to 1 year was low in both the Synergy group and the other n-DES group. Death occurred in 5.2% versus 4.5% (adjusted HR: 1.14; 95% CI: 0.96-1.36; P = 0.11) and MI in 3.2% versus 3.5%, (adjusted HR: 1.11; 95% CI: 0.93-1.33; P = 0.24) up to 1 year.
CONCLUSIONS: In a large real-life population the Synergy stent appears to be safe and effective with a low rate of restenosis and ST comparable with other n-DES. © 2017 Wiley Periodicals, Inc.
Предметные рубрики MeSH
Absorbable ImplantsAgedAngioplasty, Balloon, CoronaryChromiumCoronary AngiographyCoronary Artery DiseaseDrug-Eluting StentsEverolimusFemaleFollow-Up StudiesHumansImmunosuppressive AgentsIncidenceMalePlatinumPolymersPostoperative ComplicationsProportional Hazards ModelsProsthesis DesignRegistriesRetrospective StudiesSurvival RateSwedenTime FactorsTreatment Outcome