MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jcin.2009.11.009

Медицинская библиотека · JACC. Cardiovascular interventions · 2010

Impact of multiple and long sirolimus-eluting stent implantation on 3-year clinical outcomes in the j-Cypher Registry.

Shirai Shinichi, Kimura Takeshi, Nobuyoshi Masakiyo, Morimoto Takeshi, Ando Kenji, Soga Yoshimitsu, Yamaji Kyohei, Kondo Katsuhiro, Sakai Koyu, Arita Takeshi, Goya Masahiko, Iwabuchi Masashi, Yokoi Hiroyoshi, Nosaka Hideyuki, Mitsudo Kazuaki, j-Cypher Registry Investigators

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVES

Our aim was to study the relationships between total stent length (TSL) and long-term clinical outcomes after sirolimus-eluting stent (SES) implantation.

BACKGROUND

SES compared with bare-metal stent use for long lesion treatment is associated with reduced restenosis rates.

METHODS

Three-year follow-up data were available for 10,773 patients (14,651 lesions) that had been treated with only SES (Cypher, Cordis Corp., Warren, New Jersey) in the j-Cypher registry. Patients and lesions were divided into quartile groups: TSL per patient (Q1: 8 to 23 mm, Q2: 24 to 36 mm, Q3: 37 to 54 mm, Q4: 55 to 293 mm), and TSL per lesion (QA: 8 to 18 mm, QB: 19 to 23 mm, QC: 24 to 33 mm, QD: 34 to 150 mm).

RESULTS

In per-lesion data, longer TSL increased target lesion revascularization (TLR) rates but did not increase stent thrombosis rates (p = 0.2324). In per-patient data, the incidences of TLR remarkably increased with increasing TSL. Incidence of composite of death and myocardial infarction also increased with increasing TSL; however, after adjustment for baseline differences, there was no statistical significance. Definite stent thrombosis rate in group Q4 was significantly higher than in other groups, both unadjusted (hazard ratio: 1.770, p = 0.0081) and adjusted (hazard ratio: 1.727, p = 0.0122) for baseline differences.

CONCLUSIONS

TSL per lesion and patient had significantly impacts on TLR rates. Longer TSL per patient was associated with increased incidence of stent thrombosis through 3 years.

Для цитирования: Shirai Shinichi, Kimura Takeshi, Nobuyoshi Masakiyo, Morimoto Takeshi, Ando Kenji, Soga Yoshimitsu, Yamaji Kyohei, Kondo Katsuhiro, Sakai Koyu, Arita Takeshi, Goya Masahiko, Iwabuchi Masashi, Yokoi Hiroyoshi, Nosaka Hideyuki, Mitsudo Kazuaki, j-Cypher Registry Investigators. Impact of multiple and long sirolimus-eluting stent implantation on 3-year clinical outcomes in the j-Cypher Registry.. JACC. Cardiovascular interventions. 2010. DOI: 10.1016/j.jcin.2009.11.009.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.