OBJECTIVE

The recent integration of automated real-ear measurements (REM) in the fitting software facilitates the hearing aid fitting process. Such a fitting strategy, TargetMatch (TM), was evaluated. Test-retest reliability and matching accuracy were quantified, and compared to a REM-based fitting with manual adjustment. Also, it was investigated whether TM leads to better perceptual outcomes compared to a FirstFit (FF) approach, using software predictions only. Design and study sample: Ten hearing impaired participants were enrolled in a counterbalanced single-blinded cross-over study comparing TM and FF. Aided audibility, speech intelligibility and real-life benefits were assessed. Repeated measurements of both TM and REMs with manual adjustment were performed.

RESULTS

Compared to a REM-based fitting with manual adjustment, TM had higher test-retest reliability. Also, TM outperformed the other fitting strategies in terms of matching accuracy. Compared to a FF, improved aided audibility and real-life benefits were found. Speech intelligibility did not improve.

CONCLUSIONS

Preliminary data suggest that automated REMs increase the likelihood of meeting amplification targets compared with a FF. REMs integrated in the fitting software provide additional reliability and accuracy compared to traditional REMs. Findings need to be verified in a larger and more varied sample.

Для цитирования: Denys Sam, Latzel Matthias, Francart Tom, Wouters Jan. A preliminary investigation into hearing aid fitting based on automated real-ear measurements integrated in the fitting software: test-retest reliability, matching accuracy and perceptual outcomes.. International journal of audiology. 2018. DOI: 10.1080/14992027.2018.1543958.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.