MedElevator Войти в исследования
← Поиск публикаций
Медицинская библиотека · International journal of computerized dentistry · 2017

Adjustment of retention of all-ceramic double-crown attachments.

Schwindling Franz Sebastian, Rammelsberg Peter, Krisam Johannes, Rues Stefan

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

Double-crown attachments, such as conical crowns (CCs), can retain removable partial prostheses. Digital manufacturing enables the use of innovative materials such as zirconia, and new workflows. The aim of this study was to investigate options for the adjustment of retention forces of all-zirconia CCs.

MATERIALS AND

METHODS

Single zirconia primary crowns were produced with convergence angles (α) of 3 and 4 degrees, together with monolithic zirconia secondary crowns (n = 8 for α = 3 degrees; n = 8 for α = 4 degrees). Retention was measured by fitting the crowns with forces F = 12.5 to 100 N, and evaluating the magnitudes of the forces required for loosening (L). L/F ratios were recorded, and the coefficient of friction (µ0) was calculated. To limit the maximum force required for loosening, and to prevent high tensile stresses within the crowns, the width of the occlusal gap between the primary and secondary crowns was limited by the implementation of occlusal stops.

RESULTS

True convergence angles were more conical than expected, by approximately 0.3 degrees. For α = 3 degrees and α = 4 degrees, L/F ratios were 0.308 (SD 0.04) and 0.208 (SD 0.068), respectively. The overall coefficient of static friction was µ0 = 0.113. Maximum retention forces were successfully controlled; the average values were 12.1 N (SD 4.5 N) for zirconia occlusal stops, and 12.8 N (SD 3.3 N) for composite occlusal stops.

CONCLUSION

The clinically desired L/F ratio of 1/3 was achieved by selecting 3-degree burs for fabrication of all-zirconia CCs. It is possible to limit retention, thereby reducing tensile stress in the circumferential direction in secondary crowns.

Для цитирования: Schwindling Franz Sebastian, Rammelsberg Peter, Krisam Johannes, Rues Stefan. Adjustment of retention of all-ceramic double-crown attachments.. International journal of computerized dentistry. 2017.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.