MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/s0022-3913(09)60158-x

Медицинская библиотека · The Journal of prosthetic dentistry · 2009

Ring liner and burn-out temperature affect the clinical time required to fit a cast post.

Otun Adegbenga, Lee Heeje, Geminiani Alessandro, Shirakura Akihiko, Ercoli Carlo, Feng Changyong

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

STATEMENT OF PROBLEM: A cast post that is made with an unlined metal casting ring may exhibit anisotropic shrinkage which could result in distortion and consequently require more chair time for fitting in the root canal.

PURPOSE: The purpose of this study was to investigate whether the presence of a ring liner and the burn-out temperature of the investment material affect the clinical time required to fit a cast post.

MATERIAL AND

METHODS

Sixty identical post patterns were fabricated from a customized stainless steel root form. They were divided into 3 groups (n=20) as follows: group LH used a cellulose ring liner and a final burn-out temperature of 815 degrees C; group NH used no liner with the same temperature; group NL used no liner with a final burn-out temperature of 600 degrees C. All groups were invested in stainless steel casting rings with the same phosphate-bonded investment (Hi Temp) and cast with same alloy (Protocol). Two blinded investigators, with different levels of experience, adjusted and placed the posts in the experimental root form until a subjective acceptable fit was achieved. Each investigator fit 10 cast posts for each group, and the time required to achieve a subjective acceptable fit was measured in seconds. Two-way ANOVA was used to test the significance of the investigator, group, and their interaction. One-way ANOVA and a post hoc Tukey HSD test were used to find significant differences among the groups (alpha=.05).

RESULTS

The 2-way ANOVA showed a significant effect of the investigator (P=.001) and group (P<.001), but not interaction (P=.15). The 1-way ANOVA showed significant differences among the 3 groups (P<.001), and the Tukey HSD test showed significant differences between the following pairs: LH and NH (P=.009), and LH and NL (P<.001). NH and NL did not demonstrate a significant difference.

CONCLUSIONS

Investing a post pattern without a ring liner and setting the final burn-out temperature at 600 degrees C allow the fabrication of cast posts that require significantly less adjustment time for clinical placement than those invested with a ring liner and burned out at 815 degrees C.

Для цитирования: Otun Adegbenga, Lee Heeje, Geminiani Alessandro, Shirakura Akihiko, Ercoli Carlo, Feng Changyong. Ring liner and burn-out temperature affect the clinical time required to fit a cast post.. The Journal of prosthetic dentistry. 2009. DOI: 10.1016/s0022-3913(09)60158-x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.