m+Medelevator.RU
← Поиск публикаций
Proceedings of SPIE--the International Society for Optical Engineering · 2025

Determination of the point-of-first-interaction for an ultra-high-performance brain PET system with "onion ring" geometry.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Zheng Wei, Schmidtlein Ross, Harmon Eric S, Thompson Michael O, Krol Andrzej

Аннотация

We used the Monte Carlo GATE v9, (GEANT4) simulations to model annihilation photons interactions in our novel advanced brain-PET scanner in onion-ring geometry (US Patent 20210223414) with monolithic thin LYSO slab optically coupled to SiPM arrays to assess potential improvement of point-of-first-interaction (PFI) localization determination vs. conventional system. Three 250-mm-long cylindrical systems were evaluated: (i) 3-3-3 mm slab thicknesses concentric rings; (ii) 3-3-18 mm slab thicknesses concentric rings with 7-mm air-gaps and inner diameters of 250, 270 and 290 mm, respectively; and (iii) single-ring 24-mm-thick system with 250 mm inner diameter. The brain was simulated by a sphere of radioactive (F-18) water with 170-mm diameter confined by 8-mm thick spherical bone shell. The coincidence events studied via simulations involved photo-electric absorption (PA) and first-order Compton scatter (CS) interactions happening within predefined coincidence-time-window. If the distance between CS and PA event was shorter than the detector intrinsic spatial resolution, we considered it "pseudo single" event at energy-based averaged location (Pavg). We found that for the pseudo single events with energy deposited around 511 keV the median PFI-Pavg distance projected onto the detector plane was 0.5 mm for 3-mm ring, 0.9 mm for 18-mm ring, and 1.0 mm for 24-mm ring. We established that 3-3-3-mm system allowed obtaining more accurate depth-of-interaction (DOI) information with the mean true DOI for PFI of 1.4 mm and absolute uncertainty of 0.3 mm, as compared to the conventional 24-mm-thick single-ring system with the mean true DOI for PFI of 7.5 mm and with higher absolute uncertainty of 1.6 mm. The ratios of the number of intra-ring to inter-ring first-order Compton scattering events were lowest for the central rings (1.9 and 1.3 for 3-3-3-mm and 3-3-18-mm systems, respectively), higher for the distal and proximal rings, and strongly dependent on the ring thickness. The relative probability for forward vs. backward scattering was in the range of 60% to 89%, and 61% to 94% for 3-3-3-mm and 3-3-18-mm systems, respectively. We conclude that the spatial resolution provided by multi-ring geometries may offer substantial improvement when compared to conventional PET system designs with comparable sensitivity.

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты