MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/brs.0000000000003559

Медицинская библиотека · Spine · 2020

The Intelligent Automated Pressure-Adjustable Orthosis for Patients With Adolescent Idiopathic Scoliosis: A Bi-Center Randomized Controlled Trial.

Lin Yangmin, Lou Edmond, Lam Tsz Ping, Cheng Jack Chun-Yiu, Sin Sai Wing, Kwok Wing Kwan, Wong Man Sang

СтатьяМногоцентровое исследованиеРандомизированное исследованиеПеревод в очереди

Аннотация

STUDY

DESIGN

Randomized controlled trial.

OBJECTIVE

To compare the effectiveness of the automated pressure-adjustable orthosis (PO) and conventional orthosis (CO) for treatment of adolescent idiopathic scoliosis (AIS).

SUMMARY OF BACKGROUND DATA: Orthosis wearing quality may influence its effectiveness for AIS. An automated PO aimed to provide a more optimized and consistent biomechanical environment. Clinical evaluation was conducted to study the effectiveness of this innovative orthosis.

METHODS

Patients with AIS who met the criteria (Age 10-14, Cobb 20°-40°, and Risser sign 0-2) were recruited from two clinics and randomly assigned to the PO and CO groups. Compliance sensors were embedded in both groups, while the PO group was set to adjust the interfacial pressure as prescribed automatically. Clinical assessments (radiology and quality of life, QoL) were conducted at the baseline, immediate after orthosis fitting and 1-year follow-up. Orthosis wearing compliance was tracked using thermo and pressure sensors.

RESULTS

Twenty-four patients were enrolled with one drop-out (PO, n = 11; CO, n = 12). Significant immediate in-orthosis correction was observed in the PO (11.0° ± 6.5°, 42.0%, P < 0.001) and CO (10.3° ± 5.3°, 37.6%, P < 0.001) groups. After 1 year, no patient with PO progressed while two with CO had progression more than 5°. The mean daily wearing duration was 1.1 hours longer in the PO group as compared with the CO group (15.4 ± 4.5 vs. 14.3 ± 3.8 h). Moreover, the wearing quality within the targeted pressure was 33.9% higher in the PO group (56.5 ± 16.5% vs. 23.1 ± 12.1%, P < 0.001). No significant difference in the QoL results was observed between two groups nor within both groups during the study period.

CONCLUSION

This study showed that the automated PO could enhance wearing quality when compared with the CO, thus offering a better biomechanical corrective effect in the study period without adverse effect on the patients' wearing quantity and QoL.

LEVEL OF EVIDENCE: 1.

Для цитирования: Lin Yangmin, Lou Edmond, Lam Tsz Ping, Cheng Jack Chun-Yiu, Sin Sai Wing, Kwok Wing Kwan, Wong Man Sang. The Intelligent Automated Pressure-Adjustable Orthosis for Patients With Adolescent Idiopathic Scoliosis: A Bi-Center Randomized Controlled Trial.. Spine. 2020. DOI: 10.1097/brs.0000000000003559.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.