MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2967/jnmt.125.271414

Медицинская библиотека · Journal of nuclear medicine technology · 2026

Real-Time Imaging of 177Lu-Labeled Radiopharmaceutical Infusions with a Portable γ-Camera: Pilot Trial Results.

Oldan Jorge D, Schroeder Jennifer A, Khandani Amir, Collins Heather, Pope Justin, Huynh Robert, Ivanovic Marija, Rowe Steven P

СтатьяКлиническое исследованиеПеревод в очереди

Аннотация

Recently, it was proposed that follow-up imaging for patients treated with 177Lu-labeled radiopharmaceuticals should be focused on posttherapy SPECT/CT, given the intrinsic γ-photon emitted by 177Lu, suggesting that real-time imaging of radiopharmaceutical infusions using γ-camera technology may be feasible. In this pilot feasibility study, we used a portable γ-camera situated within our theranostics suite to visualize the infusion of 177Lu-labeled radiopharmaceuticals in real time.

Methods

Patients were consecutively enrolled between June 5, 2025, and July 17, 2025, with any patient receiving a 177Lu-based radiopharmaceutical infusion at our theranostics center being eligible for inclusion. 177Lu-based radiopharmaceuticals were administered via syringe method. A portable γ-camera was used for dynamic image acquisition. An open-energy window was used to obtain 120 frames at 30 s per frame for a total of 5 or 30 min (to include the entirety of either a 177Lu-PSMA-617 or a 177Lu-DOTATATE infusion, respectively) using a 128 × 128 matrix and a low-energy, high-resolution collimator.

Results

Six patients were imaged, and the 177Lu-labeled radiopharmaceutical was visibly confined to the venous system, with measurable time-activity curves, in all patients. No evidence of immediate complication was seen during the imaging of any of the infusions, and no findings suggest an event such as extravasation occurred.

Conclusion

Dynamic, real-time imaging of infusions of 177Lu-labeled radiopharmaceuticals with a γ-camera is feasible. Although further study is needed, this method may be useful for the early identification of complications from infusions, potentially allowing for the alleviation of toxicities and preservation of expensive radiopharmaceutical doses.

Для цитирования: Oldan Jorge D, Schroeder Jennifer A, Khandani Amir, Collins Heather, Pope Justin, Huynh Robert, Ivanovic Marija, Rowe Steven P. Real-Time Imaging of 177Lu-Labeled Radiopharmaceutical Infusions with a Portable γ-Camera: Pilot Trial Results.. Journal of nuclear medicine technology. 2026. DOI: 10.2967/jnmt.125.271414.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.