MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/s25247523

Медицинская библиотека · Sensors (Basel, Switzerland) · 2025

Resonant Capacitive MEMS Coupled to a T-Shaped Acoustic Cavity for Enhanced Photoacoustic Gas Detection.

Pages Fanny, Charensol Julien, Seoudi Tarek, Goutorbe Julie, Laporte Loni, Ayache Diba, Naoum Fadia Abou, Rosenkrantz Eric, Vicet Aurore, Bahriz Michael

СтатьяПеревод в очереди

Аннотация

To address the lack of compact and high-performance gas sensors in the literature, a miniaturized photoacoustic sensor has been developed using a resonant capacitive MEMS specifically designed for gas detection. Its performance is enhanced by coupling it to a T-shaped acoustic cavity, which confines and directs the acoustic waves toward the transducer. Electrical and photoacoustic characterizations were carried out to determine the nominal capacitance and resonance frequency of the device. The acoustic coupling resulted in a significant improvement in the transducer's mechanical response, while the linearity of the sensor was confirmed over a broad concentration range. This improvement led to a reduction in the limit of detection (LOD) from 186 ppmv to 16 ppmv. In parallel, the Normalized Noise-Equivalent Absorption (NNEA) metric improved from 1.49×10-7W·cm-1·Hz-1/2 to 1.28×10-8W·cm-1·Hz-1/2, representing a 11-fold increase in sensitivity. Stability over time is confirmed through Allan-Werle deviation analysis, confirming the reliability of the signal over extended measurement periods. These results demonstrate that coupling a resonant MEMS transducer to a well-designed acoustic cavity is an efficient strategy to significantly improve the sensitivity of photoacoustic gas detection systems.

Для цитирования: Pages Fanny, Charensol Julien, Seoudi Tarek, Goutorbe Julie, Laporte Loni, Ayache Diba, Naoum Fadia Abou, Rosenkrantz Eric, Vicet Aurore, Bahriz Michael. Resonant Capacitive MEMS Coupled to a T-Shaped Acoustic Cavity for Enhanced Photoacoustic Gas Detection.. Sensors (Basel, Switzerland). 2025. DOI: 10.3390/s25247523.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.