m+Medelevator.RU
← Поиск публикаций
Journal of thoracic disease · 2025

Holistic integrative analysis of circulatory parameters: effects of CPAP titration in patients with obstructive sleep apnea.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Chen Jia-Hao, Sun Xing-Guo, Xiang Meng-Jun, Zhang Zeng-Fei, Huang Jiang, Xie Ben, Xu Fan, Zhou Qing-Qing, Wang Ji-Nan, Zhang Yan-Fang, Shi Chao, Liu Fang, Xie You-Hong

Аннотация

BACKGROUND: The idea of Holistic Integrative Physiology and Medicine (HIPM) emphasizes integrated regulation, supporting the interconnected systems of respiration, circulation, and metabolism. This study aims to investigate the effects of continuous positive airway pressure (CPAP) on the physiological functions in patients with obstructive sleep apnea (OSA).

METHODS: This self-controlled cohort study evaluated 20 patients with OSA for 48 hours using polysomnography (PSG). Natural sleep patterns were recorded on the first night of monitoring to provide baseline physiological data. Patients were instructed to utilize CPAP on the second night. The study involved a thorough analysis and calculation of a range of physiological parameters, including those related to respiratory, circulatory, and sleep parameters. To determine how CPAP affected each patient's circulatory parameters, statistical comparisons were done between normal sleep and CPAP therapy.

RESULTS: After the CPAP titration, OSA patients' respiratory and circulatory parameters improved significantly on the second night. The apnea-hypopnea index (AHI) decreased to 4.82±3.90 events/h, heart rate (HR) averaged 60.25±7.08 bpm, systolic blood pressure (SBP) was 98.46±17.66 mmHg, and diastolic blood pressure (DBP) was 66.44±14.24 mmHg. Compared to the first night, these values significantly decreased (all P<0.001). In addition, circulatory parameter variability improved significantly (all P<0.05).

CONCLUSIONS: For patients with OSA, CPAP effectively reduces sleep apnea and related hypoxia. Moreover, it significantly improves circulatory parameters, indicating its potential as a long-term therapeutic solution.

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты