Advances in neonatal care : official journal of the National Association of Neonatal Nurses · 2020

Neonatal Nurse Practitioner Use of Ultrasonography to Verify Umbilical Venous Catheter Placement in the Neonatal Intensive Care Unit.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Mele Robert, Panesar Laurie E, Heyden Marybeth, Sridhar Shanthy, Brandon Debra

Аннотация

BACKGROUND: Literature dating back to 1982 supports the use of ultrasound to confirm UVC position as a more reliable method compared to x-ray. The use of ultrasound to confirm UVC position remains infrequent in the NICU.

PURPOSE: To determine the feasibility of training an NNP in the acquisition and interpretation of a parasternal short-axis (PSAX) image of the heart to confirm UVC position.

METHODS: A retrospective review of 48 charts evaluated descriptive data using standard technique of an x-ray to confirm UVC placement. An NNP was trained to acquire and interpret a parasternal short-axis (PSAX) cardiac view by a pediatric cardiologist. The NNP independently and prospectively evaluated 21 neonates and determined whether the UVC was in satisfactory or unsatisfactory position. The same image was blindly over-read by the pediatric cardiologist. Agreement between the NNP and pediatric cardiologist interpretations as well as the pediatric cardiologist and radiologist interpretations was evaluated using the κ-test.

RESULTS: Initial pediatric cardiology interpretation of UVC position showed the UVC to be malpositioned in 66% of neonates (n = 14). NNP and pediatric cardiology interpretations in UVC position had 86% agreement (κ-0.667). Pediatric cardiology (ultrasound) and radiology interpretations (x-ray) in UVC position had 86% agreement (κ-0.69).

IMPLICATIONS FOR PRACTICE: It is feasible to train NNPs to perform and accurately interpret a single PSAX ultrasound image to determine satisfactory UVC position.

IMPLICATIONS FOR RESEARCH: Increasing the use of ultrasound to determine satisfactory position of UVCs in the NICU can reduce unnecessary exposure to ionizing radiation in neonates.